The following tables list how Pre/Post interprets Record Fields based on the analysis type (Record 9, Field 2).

Field 2 Analysis type
0 Unknown
1 Static
3 Normal mode
4 Complex eigenvalue first order
5 Transient
6 Frequency response
7 Buckling
8 Complex eigenvalue second order
9 Static nonlinear
10 Craig-Bampton constraint modes
11 Equivalent attachment modes
12 Effective mass modes
13 Effective mass matrix
14 Effective mass matrix
15 Distributed load load distribution
16 Distributed load attachment modes
17 Static nonlinear cyclic harmonic
18 Static nonlinear axisymmetric harmonic

Each column corresponds to one of the analysis types above. The rows are the fields on records 10-13. Non-empty cells represent fields supported by the Universal File format. The background colors of the cells are fields that Pre/Post interprets with special meaning.

  • Load case or step: A unique value indicates that this dataset belongs to this load case or step.

  • Iteration: A unique value indicates that this dataset belongs to this iteration within a load case or step or, in some cases, a harmonic index or parent iteration.

  • Harmonic index: A unique value indicates that this dataset belongs to this iteration within a load case or step.

Records 10 and 11

Integer data (Records 10 and 11 ) Field Unknown Static Normal mode Complex eigenvalue first order Transient Frequency response Buckling Complex eigenvalue second order Static nonlinear Response Dynamics Static non-linear cyclic harmonic Static non-linear axisymmetric harmonic
Design set ID 1 1 X 1 X X X X X X X
Iteration number 2 X 0 X
Solution set ID 3 X Load case or step 1 Load case or step X X X Load case or step Load case or step X Load case or step Load case or step
Boundary condition 4 X X 0 X X X X X X X
Load set or Harmonic Index 5 Iteration 1 X Load case or step Load case or step Load case or step X X X Harmonic index Harmonic index
Mode number 6 1 Iteration Iteration Iteration X Iteration Iteration
Time step number 7 0 Iteration Iteration X Iteration Iteration
Frequency number 8 0 Iteration X
Creation option 9 X X 0 X X X X X X X
Number retained 10 X X 0 X X X X X X X

Records 12 and 13

Integer data (Records 12 and 13 ) Field Unknown Static Normal mode Complex eigenvalue first order Transient Frequency response Buckling Complex eigenvalue second order Static non-linear Response Dynamics Static nonlinear cyclic harmonic Static nonlinear axisymmetric harmonic
Time 1 X X X X
Frequency 2 X X X X X
Eigenvalue or Harmonic Index value 3 X X X
Modal mass 4 X X
Viscous damping ratio 5 X X
Hysteretic damping ratio 6 X X
Real part eigenvalue 7 X X
Imaginary part eigenvalue 8 X X
Real part of modal A 9 X
Real part of mass 9 X
Imaginary part of modal A 10 X
Imaginary part of mass 10 X
Real part of modal B 11 X
Real part of stiffness 11 X
Imaginary part of modal B 12 X
Imaginary part of stiffness 12 X

Example

Consider a 2414 dataset with Record 9, Field 2 set to 2 (Analysis Type – Normal Mode ). This data on record 10-13 is stored in Pre/Post as results for mode number 1 in load case (or solution step) 1 with a frequency of 1000.

Records 10 and 11

Integer data (Records 10 and 11) Field Normal mode
Design set ID 1 0
Iteration number 2 0
Solution set ID 3 1
Boundary condition 4 0
Load set or Harmonic index 5 0
Mode number 6 1
Time step number 7 0
Frequency number 8 0
Creation option 9 0
Number retained 10 0

Records 12 and 13

Integer data (Records 12 and 13) Field Normal mode
Time 1
Frequency 2 1000
Eigenvalue or Harmonic index value 3 X
Modal mass 4 X
Viscous damping ratio 5 X
Hysteretic damping ratio 6
Real part eigenvalue 7
Imaginary part eigenvalue 8
Real part of modal A 9
Real part of mass 9
Imaginary part of modal A 10
Imaginary part of mass 10
Real part of modal B 11
Real part of stiffness 11
Imaginary part of modal B 12
Imaginary part of stiffness 12
Learn more

Using universal files in post-processing

Working with ASCII universal files in post-processing

Using binary universal files in post-processing

Customizing universal dataset 2414

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area