Samcef environment > Samcef boundary conditions
Axisymmetric boundary conditions (Simcenter Samcef)
The following tables list the Pre/Post boundary conditions (loads, constraints, and solver-specific simulation objects) for structural and thermal axisymmetric, plane stress and plane strain models, the associated analysis types, and the Simcenter Samcef input file entries to which they correspond.
Loads
| Icon | Load | Supported Simcenter Samcef Solution Type | Corresponding Simcenter Samcef Input File Entry |
|---|---|---|---|
| Acceleration | Linear Static, Nonlinear Static, Buckling, Standalone Buckling | .CLM ACC | |
| Force | Linear Static, Nonlinear Static, Buckling, Standalone Buckling | .CLM CHA / FOL | |
| Pressure | Linear Static, Nonlinear Static, Buckling, Standalone Buckling | .CLM PRESS.CLM LFX/LFY/LFZ.CLM SFX/SFY/SFZ | |
| Rotation | Linear Static, Nonlinear Static, Buckling, Standalone Buckling | .CLM ROT.CLM DROT | |
| Temperature Load | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .CLM TFX | |
| Gravity | Linear Static, Nonlinear Static, Buckling, Standalone Buckling | .CLM ACC | |
| Heat Load | Heat Transfer | .CLT LOAD | |
| Surface Flux | Heat Transfer | .CLT FLUX | |
| Volume Flux | Heat Transfer | .CLT FLV | |
| Radiation | Heat Transfer | .CLT EMI TFR |
Constraints
| Icon | Constraint | Supported Simcenter Samcef Solution Type | Corresponding Simcenter Samcef Input File Entry |
|---|---|---|---|
| Enforced Displacement Constraint | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .CLM FIX.CLM DEP | |
| Fixed Constraint | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .CLM FIX | |
| Fixed Boundary Degrees of Freedom | Superelement Creation | .RET | |
| Free Boundary Degrees of Freedom | Superelement Creation | .RET FREE | |
| User Defined Constraint | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .CLM FIX.CLM DEP | |
| Manual Coupling | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .LIA | |
| Automatic Coupling | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .LIA | |
| Enforced Acceleration | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .CLM ACC | |
| Contact With Clearance | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .JEU | |
| Temperature at t =0. | Heat Transfer | .CLT TT0 | |
| Temperature | Heat Transfer | .CLT TFX | |
| Convection | Heat Transfer | .CLT TFC CONV EXP | |
| Cavity Convection | Heat Transfer | .CLT CONV EXP |
Solver Specific Simulation Objects
| Icon | Simulation Object | Supported Structural Simcenter Samcef Analysis Type | Corresponding Simcenter Samcef Input File Entry |
|---|---|---|---|
| Edge-to-Edge Contact | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling, Heat Transfer | .MCT | |
| Nodes-to-Edge Contact | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .MCT | |
| **Edge-to-Edge Gluing (Structural)**Edge-to-Edge Gluing (Thermal) | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling, Heat Transfer | .APS | |
| **Nodes-to-Edge Gluing (Structural)**Nodes-to-Edge Gluing (Thermal) | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling, Heat Transfer | .STICK /.PRITT | |
| Initial Temperature | Nonlinear Static, Heat Transfer | .CLT TIN | |
| Planarity Condition | Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling | .MPL | |
| Mean Constraint | Heat Transfer | .MCE/.MCC MEAN | |
| Imposed Flow Rate | Heat Transfer | .PHP FLW | |
| Fluid Network Definition | Heat Transfer | .FWJ | |
| Post-Processing Macro | Heat Transfer | .MCE/.MCC MACRO | |
| Nodal Capacity | Heat Transfer | .MCE/.MCC CAPA | |
| Initial Position (axisymmetrical) | Nonlinear Static | .CLM DEI | |
| Initial Speed (axisymmetrical) | Nonlinear Static | .CLM VII | |
| Initial Displacement (axisymmetrical) | Nonlinear Static | .CLM DE0 | |
| Initial Degree of Cure | Heat Transfer | .CLT |
Learn more
Support of expressions in materials, loads, and constraints (Simcenter Samcef)
Specifying the contact direction and gap clearance for the rigid-flexible contact (Simcenter Samcef)
Initial Temperature in a nonlinear and heat transfer solution (Simcenter Samcef)
Support of 4D table fields (Simcenter Samcef)
Enabling or disabling entities (Simcenter Samcef)
Enabling or disabling constraints in subcases (Simcenter Samcef)
Look up more details
Simcenter Samcef boundary conditions
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Axisymmetric boundary conditions (Simcenter Samcef), Simcenter 3D 2021.1 Series