The following tables list the Pre/Post boundary conditions (loads, constraints, and solver-specific simulation objects) for structural and thermal axisymmetric, plane stress and plane strain models, the associated analysis types, and the Simcenter Samcef input file entries to which they correspond.

Loads

Icon Load Supported Simcenter Samcef Solution Type Corresponding Simcenter Samcef Input File Entry
Acceleration Linear Static, Nonlinear Static, Buckling, Standalone Buckling .CLM ACC
Force Linear Static, Nonlinear Static, Buckling, Standalone Buckling .CLM CHA / FOL
Pressure Linear Static, Nonlinear Static, Buckling, Standalone Buckling .CLM PRESS.CLM LFX/LFY/LFZ.CLM SFX/SFY/SFZ
Rotation Linear Static, Nonlinear Static, Buckling, Standalone Buckling .CLM ROT.CLM DROT
Temperature Load Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .CLM TFX
Gravity Linear Static, Nonlinear Static, Buckling, Standalone Buckling .CLM ACC
Heat Load Heat Transfer .CLT LOAD
Surface Flux Heat Transfer .CLT FLUX
Volume Flux Heat Transfer .CLT FLV
Radiation Heat Transfer .CLT EMI TFR

Constraints

Icon Constraint Supported Simcenter Samcef Solution Type Corresponding Simcenter Samcef Input File Entry
Enforced Displacement Constraint Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .CLM FIX.CLM DEP
Fixed Constraint Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .CLM FIX
Fixed Boundary Degrees of Freedom Superelement Creation .RET
Free Boundary Degrees of Freedom Superelement Creation .RET FREE
User Defined Constraint Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .CLM FIX.CLM DEP
Manual Coupling Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .LIA
Automatic Coupling Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .LIA
Enforced Acceleration Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .CLM ACC
Contact With Clearance Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .JEU
Temperature at t =0. Heat Transfer .CLT TT0
Temperature Heat Transfer .CLT TFX
Convection Heat Transfer .CLT TFC CONV EXP
Cavity Convection Heat Transfer .CLT CONV EXP

Solver Specific Simulation Objects

Icon Simulation Object Supported Structural Simcenter Samcef Analysis Type Corresponding Simcenter Samcef Input File Entry
Edge-to-Edge Contact Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling, Heat Transfer .MCT
Nodes-to-Edge Contact Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .MCT
**Edge-to-Edge Gluing (Structural)**Edge-to-Edge Gluing (Thermal) Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling, Heat Transfer .APS
**Nodes-to-Edge Gluing (Structural)**Nodes-to-Edge Gluing (Thermal) Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling, Heat Transfer .STICK /.PRITT
Initial Temperature Nonlinear Static, Heat Transfer .CLT TIN
Planarity Condition Linear Static, Modal, Nonlinear Static, Buckling, Standalone Buckling .MPL
Mean Constraint Heat Transfer .MCE/.MCC MEAN
Imposed Flow Rate Heat Transfer .PHP FLW
Fluid Network Definition Heat Transfer .FWJ
Post-Processing Macro Heat Transfer .MCE/.MCC MACRO
Nodal Capacity Heat Transfer .MCE/.MCC CAPA
Initial Position (axisymmetrical) Nonlinear Static .CLM DEI
Initial Speed (axisymmetrical) Nonlinear Static .CLM VII
Initial Displacement (axisymmetrical) Nonlinear Static .CLM DE0
Initial Degree of Cure Heat Transfer .CLT
Learn more

Support of expressions in materials, loads, and constraints (Simcenter Samcef)

Specifying the contact direction and gap clearance for the rigid-flexible contact (Simcenter Samcef)

Initial Temperature in a nonlinear and heat transfer solution (Simcenter Samcef)

Support of 4D table fields (Simcenter Samcef)

Enabling or disabling entities (Simcenter Samcef)

Enabling or disabling constraints in subcases (Simcenter Samcef)

Look up more details

Simcenter Samcef boundary conditions

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Axisymmetric boundary conditions (Simcenter Samcef), Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1368796 · retrieved 2026-07-17