Post-processing > Post processing element and nodal results
Nodal combination options for element-nodal results
For element-nodal results, you can define specific Nodal Combination options.
Nodal combination options
| Nodal Combination Option Name | Formula | Result Units |
|---|---|---|
| Minimum | VMINnode | Unit of the result |
| Maximum | VMAXnode | |
| Absolute Minimum | │VMINnode│ if │VMINnode│ < │VMAXnode││VMAXnode│ otherwise. | |
| Absolute Maximum | │VMINnode │ if │VMINnode│ > │VMAXnode││VMAXnode│ otherwise. | |
| Arithmetic Mean | (∑Vnode) / Nshared | |
| Average | For more information, see Averaging options for elemental and grid point results. | |
| Signed Absolute Minimum | VMINnode if │VMINnode│< │VMAXnode│VMAXnode otherwise. | |
| Signed Absolute Maximum | VMINnode if │VMINnode│> │VMAXnode│VMAXnode otherwise. | |
| Sum | ∑Vnode | |
| Discontinuity | See below |
Note:
For invariant quantities (derived results, such as Von-Mises), the software performs the following operations in the following order.
For Average and Arithmetic Mean, the software averages the tensor or vector first and then evaluates the derived result.
For all maximum and minimum operations, the software evaluates the derived result first and then applies the combination operation.
Discontinuity options
| Discontinuity Option Name | Formula | Result Units |
|---|---|---|
| Relative Discontinuity | 100 x (VMAXnode - VMINnode) / (VMAXmodel - VMINmodel) | Percentage |
| Weighted Discontinuity | V1 * V2where:V1100 x (VMAXnode - VMINnode) / (VMAXmodel - VMINmodel)V2│VMAXnode│/ max (│VMAXmodel│, │VMINmodel│) | |
| Locally Balanced Discontinuity | 100 x (VMAXnode - VMINnode) / max (│VMAXnode│, │VMINnode│) | |
| Local Discontinuity | VMAXnode - VMINnode | Unit of the result |
Note:
VMINnode and VMAXnode are the minimum and maximum values at a given node.
Nshared is the total number of values at a given node.
VMINmodel and VMAXmodel are the minimum and maximum values over the whole model.
∑Vnode is the sum of the values at a node.
Discontinuity operations are not supported for invariant quantities (derived results, such as Von-Mises).
Where do I find it?
In Post View
| Application | Pre/Post |
|---|---|
| Prerequisite | Loaded results |
| Command Finder | Edit Post View |
| Location in dialog box | Post View dialog box→Result tab→Nodal Combination group |
In expressions
| Application | Pre/Post |
|---|---|
| Prerequisite | Loaded results |
| Command Finder | Reduction Reduction or Multiple Reduction dialog box→Expression Manager→Add Expression |
| Location in dialog box | Add Expression dialog box→Nodal Combination group |
In result probes
| Application | Pre/Post |
|---|---|
| Prerequisite | Loaded results |
| Command Finder | Result Probe |
| Location in dialog box | Result Probe dialog box→Selection and Averaging group |
In result variables
| Application | Pre/Post |
|---|---|
| Prerequisite | Loaded results |
| Command Finder | Result Variable |
| Location in dialog box | Result Variable dialog box→Nodal Combination group |
Learn more
Using element-nodal results to create elemental displays
Options for elemental results
Averaging options for elemental and grid point results
Options for element-nodal results
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Nodal combination options for element-nodal results, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1390899 · retrieved 2026-07-17