Superelement and DMIG representations > Superelements
Update a system model
Load base FEM representations
When you open an existing assembly FEM which includes superelements, the base FEM representations are not loaded in order to conserve system resources. You must load the base FEM representations before you can change some FEM occurrence attributes. In the Simulation Navigator, right-click the superelement representation and choose Load.
Update the superelement representation
One of the advantages of creating system models using external superelements is that, when a substructure is modified, you need only to re-solve the superelement solution for that substructure. When a mapped superelement .op2 file is modified, you must reload the superelement file before those changes can propagate to the system model.
In the Simulation Navigator, right-click the superelement representation and choose Edit Representation.
In the FE Model Component Representation dialog box, in the Super Element file group, select Reload.
Click OK.
Regenerate the base FEM approximation
If the component FEM from which the base FEM approximation derives has been modified, you can regenerate the approximation to match the updated FE topology.
If necessary, load the base FEM representation.
In the Simulation Navigator, right-click the superelement representation and choose Edit Representation.
In the FE Model Component Representation dialog box, in the Graphical Representation group, from the Display list, select Approximation of base FEM.
Select Regenerate FEM approximations.
Click OK.
How do I
Replace Base FEM components with superelements
Load and display superelement results
Learn more
Superelement analysis
Using superelements in an assembly FEM
System modeling workflow
Generating external superelements for Pre/Post system models
Replacing a component FEM with a superelement
Superelement mapping considerations
Connecting superelement boundary nodes to the residual
Superelement displays
Controlling the display of base FEM approximations
Solving the system model
Example: Assigning external superelements in the bulk data file
Example: Defining superelement connections and orientation
Post-processing system models
Creating a Simcenter Samcef superelement for Pre/Post system models
Supported system model solutions for Simcenter Samcef superelements
Look up more details
Supported system model solutions
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Update a system model, Simcenter 3D 2021.1 Series