Design variables in the model update and model update set solution processes
You can manage design variables in the Model Update solution process.
To add new design variables to the Model Update solution process create and assign them to the Simcenter Nastran SOL 200 Model Update solution and resolve the solution. The Model Update solution process reads the new design variables after refreshing the solution results referenced by the Model Update solution process. You can also use the Rapid Create Design Variables command.
When you select the Design Variables [#] node in the Simulation Navigator, the design variable information is displayed in the Correlation Details View subpanel.
| ID | Name | Label | Value | Lower Bound | Upper Bound | Weight | Physical Property | Type | Field |
|---|---|---|---|---|---|---|---|---|---|
| 22. | C_MOD | C_MOD | 1.000 | 0.500 | 2.000 | 1.000 | MAT1 2 | MAT1 | E |
| 23. | MNT_KX | MNT_KX | 1.000 | 0.500 | 2.000 | 1.000 | PELAS 30001 | PELAS | K1 |
| 24. | MNT_KY | MNT_KY | 1.000 | 0.500 | 2.000 | 1.000 | PELAS 30002 | PELAS | K1 |
In the Model Update solution process, you can do the following in the Correlation Details View subpanel:
Modify the scale factor, lower and upper bounds, and weight of design variables in the Correlation Detail View subpanel.
Fix selected design variables when their scale factor reaches a desired value.
Reset the current design variable values to the initial values of the active work solution.
How do I
Modify a design variable
Remove a design variable from the optimization
Reset the design variables
Update design variable settings in an Excel spreadsheet
View sensitivity matrix
Create design variables for the model update solution process
Create multiple physical design variables
Learn more
Create Multiple Design Variables
Look up more details
Supported design variables for model update solution process
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Design variables in the model update and model update set solution processes, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id1001316 · retrieved 2026-07-17