Command reference help topics > Solution Control Monitor dialog box(Thermal/Flow/SST/ESC/Multiphysics)
Solution Control Monitor – SimControls tab
| Controls | |
|---|---|
| Pause | Stops the solution. |
| Resume | Resumes a stopped solution, which restarts from the last iteration. |
| Parameters | |
| Flow Solver | Modifies the flow solution time step and convergence criteria parameters. **Time Step (Steady State)**Modifies the initial time step with a constant value specified in the box. Convergence CriteriaModifies the initial flow convergence residual with a constant value specified in the box. |
| Thermal Solver | Modifies the maximum allowable temperature change and convergence criteria parameters. Max Temperature ChangeModifies the initial maximum temperature change between two consecutive iterations with a constant value specified in the box. Convergence CriteriaModifies the initial convergence residual for the steady state thermal solution with a constant value specified in the box. |
| Update Parameters | Updates the parameter values used by the solvers when you click Apply. The solvers use the new values at the next solution iteration. |
Learn more
Solution Control Monitor
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Solution Control Monitor – SimControls tab, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1875637 · retrieved 2026-07-17