Command reference help topics > Interface Resistance dialog box (Thermal/SST/ESC/Multiphysics)

Interface Resistance dialog box — Edge Interface option

Option Description
Name Lets you specify a name for the simulation object.Description opens an editor that lets you type a description for the constraint.
Destination Folder
Simulation Object Container Specifies the folder in the Simulation Navigator in which the boundary condition will be stored. The list includes the root container and existing folders that you created using the New Folder command. Examples of a root container include Load Container, Constraint Container, and Simulation Object Container.
Folder Manager Displays a hierarchical listing of existing folders. To create a new folder, right-click any level of the hierarchy and choose New Folder.
Region
Group Reference Lets you apply the resistance regions to a group.For more information, see Group Reference options.
Select Object Lets you select the common edge, 1D elements, or edges of 2D elements representing the resistance.Element Selection Filtering lets you limit your element selection to the FE entity you select from the Filter Type list:0D Elements, 1D Elements lets you select only 1D elements.Element Edges lets you select only the edges of 2D elements.Note: You must select Element from the main selection Type Filter list to use the Element Selection Filtering options.Excluded lets you remove individual entities from within your selected object.
Stacked Smart Selector Methods Opens the Smart Selector Methods dialog box where you can specify a progression of smart selection filters.For more information, see Smart Selector Methods dialog box.
Magnitude
Type Specifies the method to define the additional conductances.Total ConductanceDefines the total conductance. Specify its magnitude in the Conductance box.Total ResistanceDefines the conductance as the inverse of total resistance. Specify its magnitude in the Resistance box.Conductance per LengthDefines the conductance per length. Specify its magnitude in the Conductance per Length box. The software multiplies the conductance you specify by the length of the associated primary element along the shared edge.Heat Transfer CoefficientDefines the heat transfer coefficient. Specify its magnitude in the Heat Transfer Coefficient box. The software calculates the resistance as 1 / (heat transfer coefficient x area). At the edge interface, the area is calculated as (the length of the edge interface) x (the minimum shell thickness).For more information, see Additional magnitude options.
How do I

Create an Interface Resistance

Learn more

Interface Resistance

Look up more details

Interface Resistance dialog box — Interface Between 2 Sets option

Interface Resistance dialog box — Surface Interface option

Modeling scenarios for using an Interface Resistance

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal

Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions

Interface Resistance dialog box — Edge Interface option, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id631826 · retrieved 2026-07-17