In the following procedure, a Node Map [30] node is used as an example. The number 30 in the square brackets indicates that 30 test and analysis nodes were mapped.
In the Simulation Navigator, right-click Node Map [30] node and choose Generate Matching DOF Set.Under the Solver Sets node, a new DOF set is created with the default name of 1 - Correlation 1 DOF Set. The created DOF set matches the current node map and sensor DOF settings. Sensor DOFs are mapped to analysis DOFs. Solver Sets1 - Correlation 1 DOF Set
(Optional) To rename the created DOF set to something meaningful, right-click 1 - Correlation 1 DOF Set, choose Rename and type the new name.
For more information, see DOF sets.