Samcef environment > Samcef output requests
Code ID syntax for Simcenter Samcef solver results
Simcenter Samcef results code IDs are four or five digits.
Four-digit codes example
For instance, in a Linear Static analysis, the Stress Tensor result is defined in the Simcenter Samcef documentation with the following codes:
| Physical Quantity | Volumes | Shells (med/up/low) | Beams | Rods |
|---|---|---|---|---|
| Stress Tensor | x411 | x431, x435, x436 | - | - |
In a code ID:
The first digit indicates the granularity type.1 for element-nodal support.2 for face-nodal support.3 for element support.4 for face support.7 for the critical ply (composite results only).8 for the critical ply id (composite results only).9 for XY graphs.
The second digit indicates the results type.3 for scalar results.4 for tensors.5 for vectors.
For instance, the code 1411 is the element-nodal (1) tensor (4) Stress tensor, and the code 3411 is the element (3) tensor (4) Stress tensor.
Five digits codes
For some shell codes, an extra leading digit defines the lower (or upper) skin origin of the results.
For example, code 13411 is the element stress tensor for the lower skin of shells. The code 23411 is its equivalent for the upper skin, and the code 3411 refers to the midsurface.
For more information and examples, see the elements post-processing results codes page in the Simcenter Samcef solver documentation.
Learn more
Default results (Simcenter Samcef)
Results codes in structural analyses (Simcenter Samcef Structure)
Families of results in structural and thermal output requests (Simcenter Samcef)
Results codes in thermal analysis (Simcenter Samcef Thermal)
User-defined output requests (Simcenter Samcef)
Time history graphs: nodal results (Simcenter Samcef structural nonlinear)
Time history graphs: element results (Simcenter Samcef structural nonlinear)
Time history graphs: nodal results (Simcenter Samcef linear transient)
Time history graphs: nodal results (Simcenter Samcef linear harmonic)
Time history graphs: element results (Simcenter Samcef linear transient or linear harmonic)
Time history graphs: nodal results (Simcenter Samcef thermal)
Time history graphs: element results (Simcenter Samcef thermal)
Time history graphs: superelement internal node results (Simcenter Samcef)
Time history graphs: superelement internal element results (Simcenter Samcef)
Requesting additional results for analyses (Simcenter Samcef)
Modeling objects for specific results (Simcenter Samcef)
Result codes in superelement creation analysis (Simcenter Samcef)
Post-processing Macro (Simcenter Samcef Thermal)
Composite criteria results codes in structural analyses (Simcenter Samcef)
Damage tensor output requests (Simcenter Samcef)
Macro element (Simcenter Samcef)
Grid point force output requests (Simcenter Samcef)
Reaction in output requests (Simcenter Samcef Structure)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Code ID syntax for Simcenter Samcef solver results, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1132897 · retrieved 2026-07-17