SimcenterKnowledge

Command reference help topics > Solution dialog box (Thermal/Flow/SST/ESC)

Solution dialog box — Thermal

Option Analysis/Solution Type Description
Include File
Include File Advanced ThermalAdvanced Axisymmetric ThermalAdvanced Thermal-FlowAdvanced Thermal-Flow with ESCSpace Systems Thermal Includes additional custom files to the thermal analysis. Included files can be user subroutines or files in the INPF file format.
Select File Appears when Include File is selected.Sets the location of the include file. You can only specify one file, but you can include multiple files. To include multiple files, you must create a file that names other files to include. This file is a text file that contains the path and file name of the files to include.
Duct Flow Parameters
Compressible Flow Advanced ThermalAdvanced Thermal-FlowAdvanced Thermal-Flow with ESC****Space Systems Thermal Accounts compressible effects when calculating the density and static pressure for all elements with Mach number greater than 0.1.
Additional Parameters
Ablation–Charring Material Advanced ThermalAdvanced Axisymmetric ThermalAdvanced Thermal-FlowAdvanced Thermal-Flow with ESCSpace Systems Thermal Lets you include one or more Ablation–Charring modeling objects in the solution. The number of included Ablation–Charring objects appears in parentheses.
Thermo-Optical Property State Advanced ThermalAdvanced Axisymmetric ThermalAdvanced Thermal-Flow****Space Systems Thermal Sets the thermo-optical property state that you want to use when you model optical property degradation. The state number indicates which thermo-optical properties from the Thermo-Optical Properties - State modeling objects referenced in the model the thermal solver uses during the solve.Note: By default or when an optical property does not exist for a specified state, the thermal solver uses the thermo-optical properties from the first state.
How do I

Model optical property degradation

Learn more

Solution options

Including additional input files for thermal analysis

Ablation-Charring

Look up more details

Solution dialog box —Solution Details

Solution dialog box — Solution Units

Solution dialog box — Ambient Conditions

Solution dialog box — Initial Conditions

Solution dialog box —Restart

Solution dialog box —3D Flow

Solution dialog box —Transient Setup

Solution dialog box — Results Options

Solution dialog box (Mapping) — Mapping Details

Solution dialog box (Mapping) — Optional Output

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal

Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions

Solution dialog box — Thermal , Simcenter 3D 2021.1 Series