Samcef environment > Superelements in Samcef > Creating superelements (Simcenter Samcef)
Validation of a dynamic superelement (Simcenter Samcef)
During the creation of a Dynamic superelement, you can optionally validate the superelement during the creation solve (modal analysis).
During the modal analysis run, both the whole model and the superelement-only reduced model are solved.
At the end of the solve, in the Simcenter Samcef _dy.res listing file, you can browse specific tables that compare the superelement reduced model and the original whole model: you can compare the modes of both the models:
SUPER-ELEMENT VALIDATION. COMPARISON CASE: 1 ============================================ (NR) NON REDUCED MODEL (SE) SUPER-ELEMENT MODE FREQUENCY (NR) FREQUENCY (SE) % ERROR GEN. MASS (NR) GEN. MASS (SE) % ERROR --------------------------------------------------------------------------------------- 1 2.666563E+01 2.666575E+01 0.000 2.257796E-02 2.257760E-02 0.002 2 7.349225E+01 7.349376E+01 0.002 7.897538E-03 7.896888E-03 0.008 3 1.440379E+02 1.440516E+02 0.010 4.037639E-03 4.035787E-03 0.046
You can use the Post Processing Navigator to display some results such as displacements.
Note:
In the Simcenter Samcef _dy.res listing file, you can also browse the effective masses table that lists the masses in the three directions (X, Y, and Z) of the model.
Limitations
You can validate only a Dynamic superelement.
You can impose extra Fixed Constraint, Fixed Translation Constraint, and Fixed Rotation Constraint boundary conditions for validation purposes.The boundary conditions will be added to the Superelement Validation subcase of the solution.If you do not define extra fixed boundary conditions, a free-free behavior is considered.
In the Analysis page of the creation solution, you must specify the number of eigenmodes to compute for validation. You can optionally specify the lower and upper frequency bounds.
For more information, see the superelement validation chapter in the Simcenter Samcef solver documentation.
Where do I find it?
| Application | Pre/Post |
|---|---|
| Prerequisite | A Simulation file as the work part and displayed partSimcenter Samcef as the specified solverStructural as the specified analysis typeSuperelement Creation as the specified solution typeDynamic as the specified Superelement Type |
| Location in dialog box | Analysis page → Superelement Validation check box |
Look up more details
Solution dialog box (Simcenter Samcef Superelement Creation Analysis)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Validation of a dynamic superelement (Simcenter Samcef), Simcenter 3D 2021.1 Series
© 2020 Siemens