Required modes for each event type
This table lists the modes needed for each Response Dynamics event type, depending on the excitation type and data recovery method being used.
| For this event type... | Using this data recovery method... | For this excitation type... | These modes are needed |
|---|---|---|---|
| Transient–or–Frequency | Mode displacement | Nodal force | Normal modes |
| Enforced motion | Normal modesConstraint modes Effective masses | ||
| Distributed load | Normal modesLoad distributions | ||
| Mode acceleration | Nodal force | Normal modesAttachment modes | |
| Enforced motion | Normal modesConstraint modes Effective masses Equivalent attachment modes | ||
| Distributed load | Normal modesLoad distributions Distributed attachment modes | ||
| Random | Mode displacement | Nodal force | Normal modes |
| Enforced motion | Normal modesConstraint modes Effective masses | ||
| Distributed load | Normal modesLoad distributions | ||
| Response Spectrum | Mode displacement | Enforced motion | Normal modesConstraint modes Effective masses |
| DDAM | N/A | DDAM (requires enforced motion location) | Normal modesConstraint modes |
| Quasi-Static | N/A | N/A | Distributed attachment modes |
How do I
Create an event
Clone an event
Copy an event from one Response Dynamics solution process to another
Set up sequential transient events
DDAM reference acceleration and velocity
Define multipliers to adjust the standard DDAM shock coefficients
Define custom DDAM shock coefficients
Learn more
Events
Data recovery
Excitations in cloned or copied events
Sequential transient events (continuation restart)
Quasi-Static events
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Required modes for each event type, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id630626 · retrieved 2026-07-17