SimcenterKnowledge

Post-processing > Saving and restoring the state of views > Edditing layout state data references

Data references in the Edit and Apply Layout State dialog box

The Edit and Apply Layout State dialog box lets you edit the data references in a layout state that point to the reference objects from the source FEM or Simulation file.

For each entry in the table, the following information appears:

  • Viewport—Indicates the corresponding viewport.

  • Source—Indicates the contents of the viewport, for example, a post view with a post-processing scenario () or post-processing results ().

  • Display—Lists the type of display used to visualize the result. For example, an XY plot, post view, and so on.

  • Object—Displays the type of data reference. For example, Result Post View for a viewport containing a post view, Field XY plot for an XY plot shown with data from a field, and so on.

  • Resolution statusResolved—The data references point to the required data.Unresolved—The data references point to missing or incompatible data. If you leave references unresolved, the corresponding viewports are not displayed.

The table below lists the available data references and their corresponding parameters that you can edit.

Note:

You cannot change the type of data reference through the Edit and Apply Layout State dialog box. For example, you cannot change simulation results to imported results.

Data reference Editor options
Result Post View SolutionA file browse componentMass unitLength unitTime unitTemperature unitAngle unitThermal energy unit
Post View Template Coordinate SystemPrevious coordinate system name
Meta Solution Result Meta solutionMeta solution step (optional)
Response Analysis Result Meta solutionResponse analysis event
Laminate Post Report Result Meta solutionLaminate Graphical report
Result Probe Probe
Boundary condition Visualization as Plot Contours Boundary conditionsSolutionsUnits
Curve from Associated AFU file AFU file
Curve from Sort 2 Op2 file Sort2 OP2 file
Field XY plot Part (available parts in the Simulation Navigator)FieldIndependent variable (Corresponding to the selected field)
Field XYZ plot Constant independent variable (corresponding to the selected field)PartFieldDependent variableIndependent variablesConstant Independent variables
Curve from a Result Probe Probe selector
Scenario for Data Source Slot name (read only)Data sourceData definitions (read only)
Nodal force report display Nodal force report
How do I

Edit layout state data references

Learn more

Layout state data references

Look up more details

Data references in the LSX file

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Data references in the Edit and Apply Layout State dialog box, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1196196 · retrieved 2026-07-17