FE Model Correlation and Update > Pre-test solution process > Sensor and exciter DOF selection
Display Auto-MAC results for DOF sets
In the Simulation Navigator, right-click the Candidate DOF [#] node, the Required DOF [#] node, or Sensor DOF [#] node and choose Correlate.
Click Show Auto-MAC Results Heat Map .
How do I
Select a candidate DOF set from nodes
Select required DOFs using nodes with normal DOFs
Define sensor locations and directions with large displacements
Select candidate sensor DOF from sensor configuration results
Learn more
Sensor and exciter DOF selection
Look up more details
Modal Assurance Criteria (MAC)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Display Auto-MAC results for DOF sets, Simcenter 3D 2021.1 Series