Post-processing > Post processing models with superelements
Identifying results in the presence of superelements
When you select nodes/elements from the model results in the graphics window, the node/element IDs, along with the superelement IDs, are displayed in the Identify dialog box.
You can determine whether the node is attached to the superelement (1) or to the main model (2).
You can also view the same information in the Information Window:
#------------------------------------------------------------------------------- 'Node ID : 'SE ID 'X 'Y 'Z Magnitude#-------------------------------------------------------------------------------# 2620 : 24497 0.196015 -2.46253e-05 1.03956 1.05788
#------------------------------------------------------------------------------- 'Node ID : 'SE ID 'X 'Y 'Z Magnitude#-------------------------------------------------------------------------------# 5265 : -- 0.0408317 -0.00140446 0.245124 0.248505
How do I
Load and display superelement results
Learn more
Plotting results in a model with superelements (Nastran)
Loading superelements in post processing (Simcenter Samcef)
Managing superelement representations (Simcenter Samcef)
Plotting superelements in multiple load case results (Simcenter Samcef)
Plotting results in a model with superelements (Simcenter Samcef)
Applying results in a model with superelements (Simcenter Samcef)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Identifying results in the presence of superelements, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1390843_v1 · retrieved 2026-07-17