Samcef environment > Samcef output requests
Results codes in structural analyses (Simcenter Samcef Structure)
Depending on the type of Simcenter Samcef solution, you can request to output specific results when you solve your Simcenter Samcef model. To do this, you create output request modeling objects:
Structural Linear Output Requests
Structural Modal Output Requests
Structural Buckling Output Requests
Structural Nonlinear Output Requests
Structural Dynamic Response Output Requests
Linear Transient Output Requests Nodal 9xxx
Linear Harmonic Output Requests Nodal 9xxx
You add results to your model by selecting Simcenter Samcef Families of codes. For more information on these families of codes, how to filter them, and how to use them, see Families of results in structural and thermal output requests (Simcenter Samcef).
The following tables list the available results and their equivalent Simcenter Samcef codes for structural analyses.
Note:
In the output requests dialog boxes, the Simcenter Samcef default codes are selected by default. For example, for a linear static analysis, force reaction and torque reaction are Simcenter Samcef default outputs. Thus, in the output requests dialog box, the Enable Force Reaction check box and the Enable Torque Reaction check box are selected.
Linear Static Analysis
Reaction
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point Reaction/Moment - Nodal | 221 |
| Force Reaction | 223 |
| Torque Reaction | 224 |
Temperature
| Result | Simcenter Samcef codes |
|---|---|
| Temperature | 120 |
Applied Force/Moment
| Result | Simcenter Samcef codes |
|---|---|
| Applied Force | x229 |
| Applied Moment | x230 |
Forces Moments
| Result | Simcenter Samcef codes |
|---|---|
| Shear Forces Moments | x524, x525, x251 |
| Normal Forces Moments | x437, x438 |
Stress
| Result | Simcenter Samcef codes |
|---|---|
| Stress Tensor | x411, x435, x436, x431 |
| Von Mises Equivalent Stress | x310, x390, x392 |
| Normal Stress Beams Rods | x440 |
| Shear Stress Beams | x450 |
Strain
| Result | Simcenter Samcef codes |
|---|---|
| Total Strain Tensor | x421, x446, x445, x528 |
Miscellaneous
| Result | Simcenter Samcef codes |
|---|---|
| Relative Displacements | x530 |
Composite Stress
| Result | Simcenter Samcef codes |
|---|---|
| Stress Tensor | x411, 1x411, 2x411 |
| Interlaminar Stress Tensor | x413 |
Composite Strain
| Result | Simcenter Samcef codes |
|---|---|
| Mechanical Strain Tensor | x423, 1x423, 2x423 |
| Total Strain Tensor | x421, 1x421, 2x421 |
Composite Criteria
For more details, see Composite criteria results codes in structural analyses (Simcenter Samcef).
Contact
| Result | Simcenter Samcef codes |
|---|---|
| Contact | 1305, 1306, 1307, 219, 220 |
| Normal Distance | 2051 |
Grid Point
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point Force and Reaction Force | x534, x532, x533 |
User Codes
| Result | Simcenter Samcef codes |
|---|---|
| User codes | In User Codes, you can manually add Simcenter Samcef results codes (on the whole structure only) |
Linear Modal Analysis
Temperature
| Result | Simcenter Samcef codes |
|---|---|
| Temperature | 120 |
Forces Moments
| Result | Simcenter Samcef codes |
|---|---|
| Shear Forces Moments | x524, x525, x251 |
| Normal Forces Moments | x437, x438 |
Stress
| Result | Simcenter Samcef codes |
|---|---|
| Stress Tensor | x411, x435, x436, x431 |
| Normal Stress Beams Rods | x440 |
| Shear Stress Beams | x450 |
Strain
| Result | Simcenter Samcef codes |
|---|---|
| Total Strain Tensor | x421, x446, x445, x528 |
Miscellaneous
| Result | Simcenter Samcef codes |
|---|---|
| Relative Displacements | x530 |
Energy
| Result | Simcenter Samcef codes |
|---|---|
| Strain Energy | 334 |
| Kinetic Energy | 335 |
Grid Point
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point ForceGrid Point Reaction Force | x534, x532, x533 |
User Codes
| Result | Simcenter Samcef codes |
|---|---|
| User codes | In User Codes, you can manually add Simcenter Samcef results codes (on the whole structure only) |
Linear Buckling and Linear Standalone Buckling analyses
Temperature
| Result | Simcenter Samcef codes |
|---|---|
| Temperature | 120 |
User Codes
| Result | Simcenter Samcef codes |
|---|---|
| User codes | In User Codes, you can manually add Simcenter Samcef results codes (on the whole structure only) |
Nonlinear Static Analysis
Shell Element
| Result | Simcenter Samcef codes |
|---|---|
| Element Normals (Direction Cosines) | 181 |
Reaction
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point Reaction/Moment - Nodal | 221 |
| Force Reaction | 223 |
| Torque Reaction | 224 |
Temperature
| Result | Simcenter Samcef codes |
|---|---|
| Temperature | 120 |
Applied Force/Moment
| Result | Simcenter Samcef codes |
|---|---|
| Applied Force | x229 |
| Applied Moment | x230 |
Forces Moments
| Result | Simcenter Samcef codes |
|---|---|
| Shear Forces Moments | x524, x525, x251 |
| Normal Forces Moments | x437, x438 |
Stress
| Result | Simcenter Samcef codes |
|---|---|
| Non-linear Stress Tensor | x411, x435, x436, x431x470, x472, x471 |
| Cauchy Stress Tensor | x442, x408, x478, x448 |
| Kirchhoff Stress Tensor | x454 |
| Piola Stress Tensor | x441, x407, x477, x447 |
| Biot Stress Tensor | x443, x409, x479, x449 |
| Equivalent Stress | x310, x390, x392, x391 |
| Normal Stress Beams Rods | x440 |
| Shear Stress Beams | x450 |
Strain
| Result | Simcenter Samcef codes |
|---|---|
| Total Strain Tensor | x421, x446, x445, x528 |
| Green Strain Tensor | x451, x417, x487, x457, x451 |
| Natural Strain Tensor | x452, x418, x488, x458, x452 |
| Biot Strain Tensor | x453, x419, x489, x459, x453 |
| Mechanical Strain Tensor | x423, 1x423, 2x423 |
| Plastic Strain Tensor | x425, 1x425, 2x425 |
| Equivalent Mechanical Strain Tensor | x330, 1x330, 2x330 |
| Equivalent Cumulative Plastic Strain | x320, x380, x382, x381 |
| Shell Strain Resultant | x432, x433 |
Thermal Strain
| Result | Simcenter Samcef codes |
|---|---|
| Thermal Strain Tensor | x422 |
Miscellaneous
| Result | Simcenter Samcef codes |
|---|---|
| Relative Displacements | x530 |
Composite Stress
| Result | Simcenter Samcef codes |
|---|---|
| Stress Tensor | x411, 1x411, 2x411 |
| Interlaminar Stress Tensor | x413 |
Composite Strain
| Result | Simcenter Samcef codes |
|---|---|
| Mechanical Strain Tensor | x423, 1x423, 2x423 |
| Total Strain Tensor | x421, 1x421, 2x421 |
Composite Criteria
For more details, see Composite criteria results codes in structural analyses (Simcenter Samcef).
Contact
| Result | Simcenter Samcef codes |
|---|---|
| Contact | 1305, 1306, 1307, 219, 220 |
| Normal Distance | 2051 |
Damage
| Result | Simcenter Samcef codes |
|---|---|
| Scalar Damage | x356, 1x356, 2x356 |
| Tensor Damage | x456 |
Energy
| Result | Simcenter Samcef codes |
|---|---|
| Potential Energy | x334 |
Grid Point
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point ForceGrid Point Reaction Force | x534, x532, x533 |
Gasket
| Result | Simcenter Samcef codes |
|---|---|
| Gasket Yield Stress | x845 |
| Gasket Status | 3846 |
User Codes
| Result | Simcenter Samcef codes |
|---|---|
| User codes | In User Codes, you can manually add Simcenter Samcef results codes (on the whole structure only) |
For more information, see the elements post-processing results codes and nodal post-processing results codes pages in the Simcenter Samcef solver documentation.
Linear Transient Response Analysis and Linear Harmonic Response Analysis
Reaction
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point Reaction/Moment - Nodal | 221 |
| Force Reaction | 223 |
| Torque Reaction | 224 |
Temperature
| Result | Simcenter Samcef codes |
|---|---|
| Temperature | 120 |
Stress
| Result | Simcenter Samcef codes |
|---|---|
| Stress Tensor | x411, x435, x436, x431 |
| Normal Stress Beams Rods | x440 |
| Shear Stress Beams | x450 |
Grid Point
| Result | Simcenter Samcef codes |
|---|---|
| Grid Point Force/Moment and Reaction Force/Moment | x534, x532, x533 |
User Codes
| Result | Simcenter Samcef codes |
|---|---|
| User codes | Lets you manually add Simcenter Samcef results codes to the whole structure. |
| Nodal User codes | Lets you manually add Simcenter Samcef results codes to groups of nodes. |
| Element User codes | Lets you manually add Simcenter Samcef results codes to groups of elements. |
Where do I find it?
| Application | Pre/Post |
|---|---|
| Prerequisite | A Simulation file as the work part and displayed partSimcenter Samcef as the specified solverStructural as the analysis type |
| Command Finder | Modeling Objects |
| Location in dialog box | Type list→Structural Linear Output RequestsStructural Modal Output RequestsStructural Buckling Output RequestsStructural Nonlinear Output RequestsStructural Dynamic Response Output RequestsLinear Transient Output Requests Nodal 9xxxLinear Harmonic Output Requests Nodal 9xxx |
Look up more details
Structural output requests dialog boxes (Simcenter Samcef)
Structural Output Requests User Result Code Selection dialog box (Simcenter Samcef)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Results codes in structural analyses (Simcenter Samcef Structure), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1122169 · retrieved 2026-07-17