Solver Parameters dialog box — Coupled Solver

Option Description
Communication Frequency Sets the communication frequency between the thermal and flow solvers for steady-state solutions. The specified value is the number of flow iterations which must take place before the thermal solution is performed.
Convergence Control
Maximum Temperature Change Sets the value for the maximum temperature change of any convecting element between two consecutive iterations. When the temperature change of all convecting elements between two consecutive iterations is below the specified value, the coupled solution is converged.
Global Heat Imbalance Fraction Sets the value for the normalized heat residual in convective heat exchange between successive coupled iterations. When this heat imbalance reaches a value below the specified limit, the coupled solution is converged.
Learn more

Adjusting solver parameters

Setting coupled solver parameters

Look up more details

Solver Parameters dialog box —Thermal Solver

Solver Parameters dialog box —3D Flow Solver

Solver Parameters dialog box —Radiation Parameters

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal

Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions

Solver Parameters dialog box — Coupled Solver, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id1236847 · retrieved 2026-07-17