Assumptions for the planar head loss correlations
The solver uses several correlations for computing the planar head loss depending on the geometry of the plane impeding the fluid flow moving within the fluid domain. See Screens in the Flow Solver Reference Manual for more information.
Thin perforated plate with sharp edge orifices
The following assumptions are necessary:
l/dh < 0.015 where l is the plate thickness and dh is the orifice hydraulic diameter.
Red > 105 where Red is orifice Reynolds number computed using the orifice hydraulic diameter.
Thin perforated plate with rounded edge orifices
The following assumptions are necessary:
Grid thickness is the same as orifice radius.
Red > 103 where Red is orifice Reynolds number computed using the orifice hydraulic diameter.
Thin perforated plate with beveled edge orifices
The following assumptions are necessary:
The beveled edge of the orifice is facing the flow.
The bevel angle is between 40° and 90°.
0.01 < l/dh < 0.16 where l is the plate thickness and dh is the orifice hydraulic diameter.
Red > 104 where Red is orifice Reynolds number computed using the orifice hydraulic diameter.
Metal wire screen
The following assumption is necessary:
- Red > 103 where Red is orifice Reynolds number computed using the orifice hydraulic diameter.
Silk thread screen
The following assumption is necessary:
- Red > 500 where Red is orifice Reynolds number computed using the orifice hydraulic diameter.
How do I
Define a Screen
Learn more
Planar Head Loss
Inputs to expressions
Look up more details
Auto-generated expressions
Quick links
Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions
Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Assumptions for the planar head loss correlations, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id628576 · retrieved 2026-07-17