Nastran environment > Importing and exporting Nastran data > Exporting Nastran data
Exporting enforced displacement constraints
When you export Enforced Displacement constraints that are defined with either a 4D field or a table of fields, and export the file to NX Nastran version 11.0 or later, or any version of Simcenter Nastran, the software exports the constraints using a transient load per time point method. When you export or solve your solution, Pre/Post creates one spatial pressure set for each time point. The software then uses a TABLED1 entry with an ordinate value of 0.0 for all time points except the time point at which the spatial pressure set is active.
Where do I find it?
| Application | Pre/Post |
|---|---|
| Prerequisite | A FEM or Simulation file as the work part and displayed partSimcenter Nastran or Simcenter 3D Multiphysics as the specified solver |
| Menu | File→Import→Simulation****File→Export→Simulation |
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Exporting enforced displacement constraints, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });