Duct Convection Correction modeling object
Use the Duct Convection Correction modeling object to correct the convective heat transfer coefficient that you specify when creating the Convection Coupling type of the Thermal Coupling — Convection simulation object. The Duct Convection Correction modeling object allows you to locally correct the convective heat transfer coefficient in a duct with mass flow network.
The heat transfer coefficient, h0, is corrected using the following equation:
where:
C is the specified multiplier.
Twall is the temperature of the convecting surface.
Tfluid is the temperature of the fluid in the ducts.
Tref is the specified reference temperature.
r and d are the specified temperature ratio exponent and temperature difference exponent, respectively.
You can store your duct convection corrections in a correction catalog. The correction catalog is stored in the correction.xml file. Use the Correction Catalog option to add the parameters in the Duct Convection Correction dialog box.
Note:
The correction.xml file must be stored in the same folder as the other Simcenter 3D Thermal/Flow, Simcenter 3D Electronic Systems Cooling, and Simcenter 3D Space Systems Thermal catalog files. The location of the catalog folder is, by default, the [software_installation]\NXCAE_extras\tmg\if\catalogs folder or the folder specified by the MAYA_TMG_CATALOG_DIR environment variable.
Where do I find it?
| Application | Pre/Post |
|---|---|
| Command Finder | Modeling Objects → Duct Convection Correction → Create |
| Menu | Insert → Modeling Objects → Duct Convection Correction → Create |
How do I
Create a Thermal Coupling — Convection
Define a convection coupling between duct nodes and solid faces
Learn more
Thermal Coupling — Convection types
Across gap coupling convection correlations
Inputs to expressions
Free convection correlations
Forced convection correlations
Specifying a Coupling Resolution
Using the Only Connect Overlapping Elements option
Using the Overlap Projection Direction option
Look up more details
Duct Node Convection Coupling options
Auto-generated expressions
Customizing catalogs
Thermal Coupling — Convection dialog box
Quick links
Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions
Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Duct Convection Correction modeling object, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id1400341 · retrieved 2026-07-17