Axisymmetric Solid (structural) / Plane Stress / Plane Strain physical property dialog boxes (Simcenter Samcef)
The physical properties available in the dialog box depend on the mesh collector type for which the physical property table is set.
| Physical Property Table | |
|---|---|
| Name | Sets the name of the physical property table. |
| Label | Sets a unique numerical identifier. The number is incremented automatically for the next physical property you create. |
| Properties | |
| Material | Specifies a material for the associated elements.Select a material from the list of materials assigned to the model, or click Choose material to define a new material. |
| Proportional Damping | |
| Damping Type | Specifies a damping type. No DampingNo damping.ViscousLets you define a viscous (or non-modal) damping.Hysteretic Stiffness FactorLets you define hysteretic (or structural) damping based a given stiffness factor.Hysteretic Flexibility FactorLets you define hysteretic (or structural) damping based a given flexibility factor.For more information on damping, see Damping (Simcenter Samcef). |
| Viscous Stiffness Factor (ALPHA) | Appears when Damping Type is set to Viscous.Sets the viscous stiffness factor. To define the stiffness factor as a function of time or frequency, click and choose New Field→Table. After you create the table field, you can set the scale factor by clicking Edit →Scale Factor. Note: Only nonlinear analysis supports Viscous Stiffness Factor (ALPHA) as a function of time. For other analyses, you must set the Viscous Stiffness Factor (ALPHA) to a constant. Otherwise, a warning appears in the Information window when you attempt to solve, and the time dependency is not exportedFor more information, see the ALPHA parameter of the Samcef .AMO command. |
| Viscous Mass Factor (BETA) | Appears when Damping Type is set to Viscous.Sets the viscous mass factor.For more information, see the BETA parameter of the Samcef .AMO command. |
| Hysteretic Stiffness Factor (HYST) | Appears when Damping Type is set to Hysteretic Stiffness Factor.Lets you define the damping factor.For more information, see the HYST parameter of the Samcef .AMO command. |
| Hysteretic Flexibility Factor (IHYST) | Appears when Damping Type is set to Hysteretic Flexibility Factor.Lets you define the damping factor.For more information, see the IHYST parameter of the Samcef .AMO command. |
| Critical Damping | |
| Set critical damping options to make the ratio per element lower than the critical value that you set.Note: Critical damping applies only to dynamic response analyses (linear transient and linear harmonic). It does not apply to modal analyses. | |
| Viscous Damping Ratio by Element (VDA) | Sets the viscous damping ratio using an expression, function, or constant.For more information, see the VDA parameter of the Samcef .AMO command. |
| Hysteretic Damping Ratio per Element (HDA) | Sets the hysteretic (structural) damping ratio using an expression, function, or constant.For more information, see the HDA parameter of the Samcef .AMO command. |
| Default Thickness | Sets the default thickness.For more information, see the THICK parameter of the Samcef .PHP command. |
| Non-Structural Mass | Sets the non-structural mass.For more information, see the NSM parameter of the Samcef .AEL command. |
| Area | Sets the rod section area. |
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Axisymmetric Solid (structural) / Plane Stress / Plane Strain physical property dialog boxes (Simcenter Samcef), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1368220 · retrieved 2026-07-17