Samcef environment > Simcenter Samcef import
Importing functions to fields or expressions (Simcenter Samcef)
You can import Simcenter Samcef .FCT functions but with some limitations.
Supported .FCT functions types
You can import the following function types:
| Samcef .FCT type | Supported parameters | Notes |
|---|---|---|
| X-Y Tabulated | ABS, ORDOCOUPLES | Imported as table fields.Functions up to 3 variables: CREE VALEURS Y U [V] [W]. |
| Polynomial | BORNES, POLBORNES, PO2 | Imported as expressions.Only functions of 1 variable: CREE VALEURS Y U. |
| Analytical | BORNES, ANALYTIC "...." | Imported as expressions. |
| Constant | BORNES, CON | Imported as expressions. |
| Linear | BORNES, LIN | Imported as expressions. |
| Quadratic | BORNES, QUA | Imported as expressions. |
| Sine | BORNES, SIN | Imported as expressions. |
| Cosine | BORNES, COS | Imported as expressions. |
For analytical functions, the following math operators are supported:
| Samcef mathematical operators | Pre/Post mathematical operators |
|---|---|
| - | - |
| * | * |
| / | / |
| ** | ^ (exponent) |
| SQR | sqrt |
| LN | log |
| LOG | log10 |
| EXP | exp |
| ABS | abs |
| MIN | minimum |
| MAX | max |
| SIN | sin |
| COS | cos |
| TAN | tan |
| ASIN | asine |
| ACOS | acosine |
| ATAN | atangent |
| SINDNOTE | sin |
| COSD | cos |
| TAND | tan |
| ASIND | asine |
| ACOSD | acosine |
| ATAND | atangent |
| DINH | hypsin |
| COSH | hypcos |
| TANH | hyptan |
| INT | floor |
| NINT | round |
| MOD | mod |
| SIGN | sign |
| PI | PI |
For more information on these operators, see Mathematical functions in expressions.
Piecewise .FCT functions
You can import piecewise functions if each piece's definition only uses one of the following parameters:
ANALYTIC
CON, LIN, QUAD, SIN, or COS
POL or POL2
Note:
You cannot use X-Y tabulated definitions in a piecewise function.
Domains support
The following table describes the supported Simcenter Samcef dependency domains.
| Samcef domain | Pre/Post domain |
|---|---|
| TIME | Time |
| TEMP | Temperature |
| CUR | Degree of cure |
| GLT | Glass transition temperature |
The following Simcenter Samcef domains are not supported:
| Samcef domain | Notes |
|---|---|
| TMOY | Average temperature |
| TBUL | Bulk (fluid) temperature |
| CRYS | Degree of crystalization |
| PRAN | Prandt number |
| REY | Reynolds number |
| VTEMP | Cooling rate |
For more information, see the Samcef .FCT command.
Look up more details
File Import dialog box (Simcenter Samcef)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Importing functions to fields or expressions (Simcenter Samcef), Simcenter 3D 2021.1 Series
© 2020 Siemens
Argument in degrees.
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1127151 · retrieved 2026-07-17