The updated property, P, is computed as follows:
P = C0 + Coef ∙ B ∙Xini
where:
C0 is the constant term specified in the design variable modeling object.
Coef is the linear relation coefficient specified in the design variable modeling object.
B is the current value of the design variable calculated from the optimization process.
Xini is the initial value specified in the design variable modeling object.