SimcenterKnowledge

Boundary conditions > Structural constraints > Simcenter Samcef structural constraints

User defined constraint (Simcenter Samcef)

The User Defined Constraint lets you define constraints for up to six degrees of freedom (DOF). The DOF correspond to the nodal displacement coordinate system.

For example, if a node belongs to a solid element, it has three translational DOF. If the Cartesian coordinate system is used, these DOF correspond to X, Y, and Z directions.

Each DOF can be set to fixed, free, or a displacement value.

DOF Corresponding Simcenter Samcef input file entry
Free n/a
Fixed .CLM FIX NOEUD - C 1/2/3/4/5/6
Displacement .CLM DEP NOEUD - C 1/2/3 V -
Rotation .CLM DEP NOEUD - C 4/5/6 V -

Where do I find it?

Application Pre/Post
Prerequisite A Simcenter Samcef simulation file as the work part and displayed part and a solution active
Command Finder User Defined Constraint
Simulation Navigator Right-click the Constraint container→New ConstraintUser Defined Constraint
Look up more details

User Defined Constraint dialog box

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

User defined constraint (Simcenter Samcef), Simcenter 3D 2021.1 Series