SimcenterKnowledge

Specialist Durability > Specialist durability load events

Supported solution types for load events

The following table lists the supported solution types for Specialist Durability load events. Blank cells indicate that the solution type is not supported.

Solver Solution type Block load event Superposition load event Transient load event
Simcenter Nastran SOL 101 - Linear Statics
SOL 109 - Direct Transient Response
SOL 112 - Modal Transient Response
SOL 129 - Nonlinear Transient Response ✓NOTE
SOL 401 - Multi-Step Nonlinear
SOL 402 - Multi-Step Nonlinear Kinematic ✓NOTE
SOL 601, 106 Advanced Nonlinear Statics
SOL 601, 129 Advanced Nonlinear Transient
Simcenter Samcef Linear Static Analysis
Nonlinear Analysis
ANSYS Linear Statics
Nonlinear Statics
Transient Dynamic
Abaqus General Analysis
Ideas Unv IDEAS UNV

Note:

  • For the supported versions of each solver, see Solver version support.

  • Mixed-order elements are not supported in Specialist Durability post processing.

  • Ply stresses are only supported for Simcenter Samcef solution results.

How do I

Create a temperature source load for part of the model

Create a temperature source load for the entire model

Automatically create a duty cycle load event

Create a random data source

Create a vibration input

Create a random load event

Create a harmonic data source

Create a harmonic load event

Learn more

Creating a temperature source load

Creating a block load event

Creating a superposition event

Creating a transient event

Creating a flexible body event

Creating a duty cycle load event

Automatically creating a duty cycle load event

Creating a random load event

Creating a harmonic load event

Managing specialist durability load events

Look up more details

Modal basis in vibration load events definition

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Supported solution types for load events, Simcenter 3D 2021.1 Series

© 2020 Siemens

The load event supports this solution type if it contains only transient subcases.

The load event supports this solution type if it contains only transient subcases.

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1756096 · retrieved 2026-07-17