Abaqus environment > Abaqus analysis types > Cyclic symmetry analysis in Abaqus
Abaqus workflow—cyclic symmetric analysis
| Step | Summary | Detailed help topic | |
|---|---|---|---|
| 1. | Set up the cyclic symmetric model | Define a 3D solid that represents a portion of the entire model. | |
| 2. | (Optional) Define the global cyclic analysis coordinate system | When you create or edit the FEM, create a global cyclic analysis coordinate system to define the axial direction for the model. | Simulation coordinate systemsCreate coordinate systems |
| 3. | Create the Abaqus solution | Create a new solution with Solver set to Abaqus and Analysis Type set to Structural or Thermal. | Create or modify a solution |
| 4. | (Optional) For a Structural Frequency Perturbation solution type, set up the Cyclic Symmetry Modes options | Specify the cyclic symmetry modes to be considered in the analysis. | Create or modify a solution step or subcaseSolution Step dialog box (Abaqus), Cyclic Symmetry Modes page |
| 5. | Create the Cyclic Symmetry simulation object to define the segments | Use the Cyclic Symmetry command to define the regions, set tolerances, and define optional parameters for slave nodes. | Define cyclic symmetry in Abaqus using the Manual methodDefine cyclic symmetry in Abaqus using the Automatic method |
| 6. | Solve and post-process the results | Solve the solution and view the results in post-processing. | Solve the modelSet up a cyclic symmetric display |
How do I
Define cyclic symmetry in Abaqus using the Automatic method
Define cyclic symmetry in Abaqus using the Manual method
Learn more
Cyclic symmetry analysis in Abaqus
Defining cyclic symmetry analysis in Abaqus
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Abaqus workflow—cyclic symmetric analysis, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });