SimcenterKnowledge

Boundary conditions > Solver sets > Temperature sets

Create a temperature set

You can create a temperature set in the Solver Sets folder or in the solution or subcase. This example shows how to create an Initial/Stress Free Temperature type of Temperature Set.

  1. In the Simulation Navigator, do one of the following:Right-click the Solver Sets folder and choose NewTemperature Set.Right-click the Temperatures container in the active solution or subcase and choose New Load SetTemperature Set.Right-click the Loads container in the active solution or subcase and choose New Load SetTemperature Set.

  2. In the Temperature Set dialog box, from the Type list, select Initial/Stress Free Temperature.

  3. In the Default Temperature box, enter a temperature.The default temperature is applied to all nodes that are not specified with the Temperature command.

  4. Click OK or Apply.