Samcef environment > Simcenter Samcef import
Common issues when importing a model (Simcenter Samcef)
This topic describes the most common issues you might face when importing a Simcenter Samcef model. It also explains when the import automatically fixes these issues, and when you must take corrective action.
For many issues, a self-explanatory message appears in the Simcenter 3D Information window.
Files generated during the import
| File | Description |
|---|---|
| Simcenter Samcef .dat bank file | The Simcenter Samcef model file that you want to import.The Simcenter Samcef pre-processor analyzes it and creates the .datx parsed XML file, which is ready for import. |
| Simcenter Samcef .datx file | The XML file that will be imported. |
| Simcenter Samcef _expnx.log file | The log of the Simcenter Samcef run that analyzes the model to import. |
Unsupported entities
For information on how unsupported entities are handled during the import, see Storing unsupported parameters and commands at import (Simcenter Samcef).
Errors, warnings, and information messages
Tip:
To quickly locate error, warning, and information messages in the log file, search for the percent symbol (%).These messages are preceded by %%%.
| Message type | Explanation |
|---|---|
| Error | A severe problem occurred that, in general, cannot be fixed automatically.Typically, you must either take corrective action in the Simcenter Samcef model and import it again, or you must fix the Simcenter 3D model after the import.In some cases, the import takes corrective action automatically.Example: Error: The functions must be the same for all the components of a Rotation Load. Only one function is imported. |
| Warning | A problem occurred, but the import took corrective action to fix it.The message describes both the problem and the fix. Most of the time, these warnings reflect data that Simcenter 3D does not support.Example: Warning: Quadratic Mindlin Shell elements are not supported by Simcenter 3D. They have been imported as Quadratic Heterosis Shell elements. |
| Info | An informative message was generated.This type of message sometimes describes a simple corrective action that the import automatically took. No corrective action is typically needed.Example: Info: Automatic choice of the analysis and solution types has been activated, but no way to do a judicious choice. Default are chosen. |
Issues related to the import process
| Message type | Details | ||||
|---|---|---|---|---|---|
| Error | Message: No Simcenter Samcef Feature in your License or all Simcenter Samcef Features are currently used.Explanation: The import did not find a valid license to launch the conversion of the Simcenter Samcef model.Action: Fix the license problem and import your Simcenter Samcef model again.Message: Error importing Simcenter Samcef file : Impossible to open the file : datx not created.Explanation: The import of a Simcenter Samcef model failed during the Simcenter Samcef solver run and the import cannot find any valid .datx file.Action: Check the _expnx.log log file to fix the problem and import the model again.Message: Error importing Simcenter Samcef file : Impossible to open the file.Explanation: Either the bank file failed to import or the datx file cannot be found.Action: Check the _expnx.log log file to fix the problem. You can also check the Options tab of the Simcenter Samcef File Import dialog box (file name, working directory, and so on) and import the model again.Message: Bad datx file.Explanation: The .datx file is corrupted.Action: Check the _expnx.log log file to fix the problem and import the model again. | Message: No Simcenter Samcef Feature in your License or all Simcenter Samcef Features are currently used.Explanation: The import did not find a valid license to launch the conversion of the Simcenter Samcef model.Action: Fix the license problem and import your Simcenter Samcef model again. | Message: Error importing Simcenter Samcef file : Impossible to open the file : datx not created.Explanation: The import of a Simcenter Samcef model failed during the Simcenter Samcef solver run and the import cannot find any valid .datx file.Action: Check the _expnx.log log file to fix the problem and import the model again. | Message: Error importing Simcenter Samcef file : Impossible to open the file.Explanation: Either the bank file failed to import or the datx file cannot be found.Action: Check the _expnx.log log file to fix the problem. You can also check the Options tab of the Simcenter Samcef File Import dialog box (file name, working directory, and so on) and import the model again. | Message: Bad datx file.Explanation: The .datx file is corrupted.Action: Check the _expnx.log log file to fix the problem and import the model again. |
| Message: No Simcenter Samcef Feature in your License or all Simcenter Samcef Features are currently used.Explanation: The import did not find a valid license to launch the conversion of the Simcenter Samcef model.Action: Fix the license problem and import your Simcenter Samcef model again. | |||||
| Message: Error importing Simcenter Samcef file : Impossible to open the file : datx not created.Explanation: The import of a Simcenter Samcef model failed during the Simcenter Samcef solver run and the import cannot find any valid .datx file.Action: Check the _expnx.log log file to fix the problem and import the model again. | |||||
| Message: Error importing Simcenter Samcef file : Impossible to open the file.Explanation: Either the bank file failed to import or the datx file cannot be found.Action: Check the _expnx.log log file to fix the problem. You can also check the Options tab of the Simcenter Samcef File Import dialog box (file name, working directory, and so on) and import the model again. | |||||
| Message: Bad datx file.Explanation: The .datx file is corrupted.Action: Check the _expnx.log log file to fix the problem and import the model again. |
Issues related to importing meshes
| Message type | Details | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Error | Message: No Family for Element: Explanation: The imported element has no equivalent in Simcenter 3D. The element is ignored, which can create other issues.Action: Fix your Simcenter Samcef model and import it again.Message: Error when creating element collector : No Mesh Collector, type = Message: Impossible to create a Mesh Collector for typeMessage: No Element Collector, type = Explanation: There is no element/mesh collector suitable for the Simcenter Samcef .HYP hypothesis that the import reads.Action: The import tries another strategy (Try to create it with element neutral name) or fails (No Element Collector, type = ). Message: Beam orientation node not set.Explanation: For the imported beam element, the import failed to find the orientation node. Most of the time, this is due to a bad Simcenter Samcef model.Action: Fix your Simcenter Samcef model and import it again.Message: Error when computing shift between Simcenter Samcef and Simcenter 3D beams : No section found, eccentricity of beam will not be corrected.Explanation: The import tried to position the imported beam but no section data could be found. This mostly occurs for imported Simcenter Samcef beams that use an unsupported section definition.Action: Fix your Simcenter Samcef model and import it again.Message: Collector has been transformed into a 3D collector. Check the model: only the topology is importedExplanation: The Simcenter Samcef model contains a mix of axisymmetric and 3D elements. This characteristic is not supported in Simcenter 3D. As a result, only the topology is imported; all other data are ignored.Action: Fix your Simcenter Samcef model and import it again.Message: Error when setting second CM flags for Mean Element: Unsupported value. Value set to 123Explanation: For a small number of mesh properties (for instance, the CM parameter of the .AEL command), Simcenter Samcef offers more options than Simcenter 3D. The import chose a default instead of the specified value.Action: Check your imported model to see if the default value affects the behavior of your model.Message: Error when creating element : Bad number of nodes for element :Explanation: An element has a topology that does not exist in Simcenter 3D. The element was ignored.Action: Fix your Simcenter Samcef model and import it again.Message: Error with 0D element orientation : Axis system not found.Explanation: A 0D element has no axis system in the Simcenter Samcef model and cannot be imported into Simcenter 3D.Action: Fix your Simcenter Samcef model and import it again. | Message: No Family for Element: Explanation: The imported element has no equivalent in Simcenter 3D. The element is ignored, which can create other issues.Action: Fix your Simcenter Samcef model and import it again. | Message: Error when creating element collector : No Mesh Collector, type = Message: Impossible to create a Mesh Collector for typeMessage: No Element Collector, type = Explanation: There is no element/mesh collector suitable for the Simcenter Samcef .HYP hypothesis that the import reads.Action: The import tries another strategy (Try to create it with element neutral name) or fails (No Element Collector, type = ). | Message: Beam orientation node not set.Explanation: For the imported beam element, the import failed to find the orientation node. Most of the time, this is due to a bad Simcenter Samcef model.Action: Fix your Simcenter Samcef model and import it again. | Message: Error when computing shift between Simcenter Samcef and Simcenter 3D beams : No section found, eccentricity of beam will not be corrected.Explanation: The import tried to position the imported beam but no section data could be found. This mostly occurs for imported Simcenter Samcef beams that use an unsupported section definition.Action: Fix your Simcenter Samcef model and import it again. | Message: Collector has been transformed into a 3D collector. Check the model: only the topology is importedExplanation: The Simcenter Samcef model contains a mix of axisymmetric and 3D elements. This characteristic is not supported in Simcenter 3D. As a result, only the topology is imported; all other data are ignored.Action: Fix your Simcenter Samcef model and import it again. | Message: Error when setting second CM flags for Mean Element: Unsupported value. Value set to 123Explanation: For a small number of mesh properties (for instance, the CM parameter of the .AEL command), Simcenter Samcef offers more options than Simcenter 3D. The import chose a default instead of the specified value.Action: Check your imported model to see if the default value affects the behavior of your model. | Message: Error when creating element : Bad number of nodes for element :Explanation: An element has a topology that does not exist in Simcenter 3D. The element was ignored.Action: Fix your Simcenter Samcef model and import it again. | Message: Error with 0D element orientation : Axis system not found.Explanation: A 0D element has no axis system in the Simcenter Samcef model and cannot be imported into Simcenter 3D.Action: Fix your Simcenter Samcef model and import it again. |
| Message: No Family for Element: Explanation: The imported element has no equivalent in Simcenter 3D. The element is ignored, which can create other issues.Action: Fix your Simcenter Samcef model and import it again. | |||||||||
| Message: Error when creating element collector : No Mesh Collector, type = Message: Impossible to create a Mesh Collector for typeMessage: No Element Collector, type = Explanation: There is no element/mesh collector suitable for the Simcenter Samcef .HYP hypothesis that the import reads.Action: The import tries another strategy (Try to create it with element neutral name) or fails (No Element Collector, type = ). | |||||||||
| Message: Beam orientation node not set.Explanation: For the imported beam element, the import failed to find the orientation node. Most of the time, this is due to a bad Simcenter Samcef model.Action: Fix your Simcenter Samcef model and import it again. | |||||||||
| Message: Error when computing shift between Simcenter Samcef and Simcenter 3D beams : No section found, eccentricity of beam will not be corrected.Explanation: The import tried to position the imported beam but no section data could be found. This mostly occurs for imported Simcenter Samcef beams that use an unsupported section definition.Action: Fix your Simcenter Samcef model and import it again. | |||||||||
| Message: Collector has been transformed into a 3D collector. Check the model: only the topology is importedExplanation: The Simcenter Samcef model contains a mix of axisymmetric and 3D elements. This characteristic is not supported in Simcenter 3D. As a result, only the topology is imported; all other data are ignored.Action: Fix your Simcenter Samcef model and import it again. | |||||||||
| Message: Error when setting second CM flags for Mean Element: Unsupported value. Value set to 123Explanation: For a small number of mesh properties (for instance, the CM parameter of the .AEL command), Simcenter Samcef offers more options than Simcenter 3D. The import chose a default instead of the specified value.Action: Check your imported model to see if the default value affects the behavior of your model. | |||||||||
| Message: Error when creating element : Bad number of nodes for element :Explanation: An element has a topology that does not exist in Simcenter 3D. The element was ignored.Action: Fix your Simcenter Samcef model and import it again. | |||||||||
| Message: Error with 0D element orientation : Axis system not found.Explanation: A 0D element has no axis system in the Simcenter Samcef model and cannot be imported into Simcenter 3D.Action: Fix your Simcenter Samcef model and import it again. | |||||||||
| Warning | Message: Quadratic Mindlin Shell elements are not supported by Simcenter 3D. They have been imported as Quadratic Heterosis Shell elements.Explanation: Simcenter Samcef allows second-degree Mindlin shells but Simcenter 3D does not. The import converted these Mindlin shells to Heterosis shells.Message: Warning when setting mesh properties : the following property is not imported in Structural Analysis.Explanation: The imported element property (.AEL command) attached to the mesh was not suitable for that analysis.Message: A table has been created to set the Material Orientation to the mesh. In Simcenter 3D, you will have to make the fem displayed, otherwise the material orientation will be wrong.Explanation: By default, when the import stops, the SIM is displayed, but not the Fem. Simcenter 3D cannot correctly display the material orientation until the Fem is also displayed. | Message: Quadratic Mindlin Shell elements are not supported by Simcenter 3D. They have been imported as Quadratic Heterosis Shell elements.Explanation: Simcenter Samcef allows second-degree Mindlin shells but Simcenter 3D does not. The import converted these Mindlin shells to Heterosis shells. | Message: Warning when setting mesh properties : the following property is not imported in Structural Analysis.Explanation: The imported element property (.AEL command) attached to the mesh was not suitable for that analysis. | Message: A table has been created to set the Material Orientation to the mesh. In Simcenter 3D, you will have to make the fem displayed, otherwise the material orientation will be wrong.Explanation: By default, when the import stops, the SIM is displayed, but not the Fem. Simcenter 3D cannot correctly display the material orientation until the Fem is also displayed. | |||||
| Message: Quadratic Mindlin Shell elements are not supported by Simcenter 3D. They have been imported as Quadratic Heterosis Shell elements.Explanation: Simcenter Samcef allows second-degree Mindlin shells but Simcenter 3D does not. The import converted these Mindlin shells to Heterosis shells. | |||||||||
| Message: Warning when setting mesh properties : the following property is not imported in Structural Analysis.Explanation: The imported element property (.AEL command) attached to the mesh was not suitable for that analysis. | |||||||||
| Message: A table has been created to set the Material Orientation to the mesh. In Simcenter 3D, you will have to make the fem displayed, otherwise the material orientation will be wrong.Explanation: By default, when the import stops, the SIM is displayed, but not the Fem. Simcenter 3D cannot correctly display the material orientation until the Fem is also displayed. |
Issues related to importing groups and regions
| Message type | Details | |||
|---|---|---|---|---|
| Error | Message: The group number cannot be importedExplanation: In the Simcenter Samcef File Import dialog box, you chose to import groups, but this group is only attached to data that has been rejected in the User Defined Text epilog file.Action: Fix your Simcenter Samcef model and import it again.Message: Error while setting Element Face Region : No target set for the faces Region:Explanation: A Simcenter Samcef macro command uses a group of faces that are not allowed in Simcenter 3D, such as a group of faces of 1D elements. This problem can also occur for a group of edges. The import did not create the region.Action: Edit your Simcenter 3D model and correct the simulation object by redefining the missing region.Message: Error while setting the supports for Node Region :Explanation: One or more nodes of the imported model do not exist in Simcenter 3D. This can also apply to a group of elements, edges, or faces.Action: Fix your Simcenter Samcef model and import it again. | Message: The group number cannot be importedExplanation: In the Simcenter Samcef File Import dialog box, you chose to import groups, but this group is only attached to data that has been rejected in the User Defined Text epilog file.Action: Fix your Simcenter Samcef model and import it again. | Message: Error while setting Element Face Region : No target set for the faces Region:Explanation: A Simcenter Samcef macro command uses a group of faces that are not allowed in Simcenter 3D, such as a group of faces of 1D elements. This problem can also occur for a group of edges. The import did not create the region.Action: Edit your Simcenter 3D model and correct the simulation object by redefining the missing region. | Message: Error while setting the supports for Node Region :Explanation: One or more nodes of the imported model do not exist in Simcenter 3D. This can also apply to a group of elements, edges, or faces.Action: Fix your Simcenter Samcef model and import it again. |
| Message: The group number cannot be importedExplanation: In the Simcenter Samcef File Import dialog box, you chose to import groups, but this group is only attached to data that has been rejected in the User Defined Text epilog file.Action: Fix your Simcenter Samcef model and import it again. | ||||
| Message: Error while setting Element Face Region : No target set for the faces Region:Explanation: A Simcenter Samcef macro command uses a group of faces that are not allowed in Simcenter 3D, such as a group of faces of 1D elements. This problem can also occur for a group of edges. The import did not create the region.Action: Edit your Simcenter 3D model and correct the simulation object by redefining the missing region. | ||||
| Message: Error while setting the supports for Node Region :Explanation: One or more nodes of the imported model do not exist in Simcenter 3D. This can also apply to a group of elements, edges, or faces.Action: Fix your Simcenter Samcef model and import it again. |
Issues related to importing materials
| Message type | Details | ||
|---|---|---|---|
| Error | Message: Error while setting material property : an Analytical function is found for the following property; Analytical functions are not imported for material properties, property set toExplanation: A material property refers to a Simcenter Samcef analytical .FCT function and the import could not handle it. A default scalar value was used instead.Action: Edit your Simcenter Samcef model, change the analytical function into a new one by adding the suitable .FCT parameters; use this new function in your material property, and then import your Simcenter Samcef model again.Message: Error while setting material property : No function can be found for Property !Explanation: A material property refers to an unknown or not imported function.Action: Fix your Simcenter Samcef model and import it again, or fix your Simcenter 3D model. | Message: Error while setting material property : an Analytical function is found for the following property; Analytical functions are not imported for material properties, property set toExplanation: A material property refers to a Simcenter Samcef analytical .FCT function and the import could not handle it. A default scalar value was used instead.Action: Edit your Simcenter Samcef model, change the analytical function into a new one by adding the suitable .FCT parameters; use this new function in your material property, and then import your Simcenter Samcef model again. | Message: Error while setting material property : No function can be found for Property !Explanation: A material property refers to an unknown or not imported function.Action: Fix your Simcenter Samcef model and import it again, or fix your Simcenter 3D model. |
| Message: Error while setting material property : an Analytical function is found for the following property; Analytical functions are not imported for material properties, property set toExplanation: A material property refers to a Simcenter Samcef analytical .FCT function and the import could not handle it. A default scalar value was used instead.Action: Edit your Simcenter Samcef model, change the analytical function into a new one by adding the suitable .FCT parameters; use this new function in your material property, and then import your Simcenter Samcef model again. | |||
| Message: Error while setting material property : No function can be found for Property !Explanation: A material property refers to an unknown or not imported function.Action: Fix your Simcenter Samcef model and import it again, or fix your Simcenter 3D model. |
Issues related to importing physical properties
| Message type | Details | |||
|---|---|---|---|---|
| Error | Message: Composite volumique shell not supported Explanation: The composite volume shell .HYP hypothesis is not supported. The import set the volume one (Solid Laminate).This message can also occur for a few other unsupported .HYP hypotheses.Action: Fix your Simcenter Samcef model and import it again.Message: Error when setting the following physical property. Physical properties will be not completely imported.Message: Error when setting the following physical property. The property is not imported.Explanation: The import process failed to import some physical properties of the mesh. The physical property table may be incomplete. Action: Check your Simcenter 3D model and complete the missing physical properties.Message: Imported functions not found.Explanation: A physical property refers to a .FCT function that was not imported. The entire physical property table is ignored or left incomplete.Action: Check your Simcenter 3D model and complete the missing physical properties. | Message: Composite volumique shell not supported Explanation: The composite volume shell .HYP hypothesis is not supported. The import set the volume one (Solid Laminate).This message can also occur for a few other unsupported .HYP hypotheses.Action: Fix your Simcenter Samcef model and import it again. | Message: Error when setting the following physical property. Physical properties will be not completely imported.Message: Error when setting the following physical property. The property is not imported.Explanation: The import process failed to import some physical properties of the mesh. The physical property table may be incomplete. Action: Check your Simcenter 3D model and complete the missing physical properties. | Message: Imported functions not found.Explanation: A physical property refers to a .FCT function that was not imported. The entire physical property table is ignored or left incomplete.Action: Check your Simcenter 3D model and complete the missing physical properties. |
| Message: Composite volumique shell not supported Explanation: The composite volume shell .HYP hypothesis is not supported. The import set the volume one (Solid Laminate).This message can also occur for a few other unsupported .HYP hypotheses.Action: Fix your Simcenter Samcef model and import it again. | ||||
| Message: Error when setting the following physical property. Physical properties will be not completely imported.Message: Error when setting the following physical property. The property is not imported.Explanation: The import process failed to import some physical properties of the mesh. The physical property table may be incomplete. Action: Check your Simcenter 3D model and complete the missing physical properties. | ||||
| Message: Imported functions not found.Explanation: A physical property refers to a .FCT function that was not imported. The entire physical property table is ignored or left incomplete.Action: Check your Simcenter 3D model and complete the missing physical properties. | ||||
| Info | Message: Properties of initial Ply 1 has been transferred to ply: 22Explanation: Specific rules are applied when importing Simcenter Samcef composite data to fit Simcenter 3D layup definitions. A ply renumbering can occur during the import.For more information, see Importing laminates (Simcenter Samcef). | Message: Properties of initial Ply 1 has been transferred to ply: 22Explanation: Specific rules are applied when importing Simcenter Samcef composite data to fit Simcenter 3D layup definitions. A ply renumbering can occur during the import.For more information, see Importing laminates (Simcenter Samcef). | ||
| Message: Properties of initial Ply 1 has been transferred to ply: 22Explanation: Specific rules are applied when importing Simcenter Samcef composite data to fit Simcenter 3D layup definitions. A ply renumbering can occur during the import.For more information, see Importing laminates (Simcenter Samcef). |
Issues related to importing functions
| Message type | Details | |||
|---|---|---|---|---|
| Error | Message: Error importing function : too many independent variables to create the table.Explanation: The import can only parse .FCT functions of two variables (U V) or fewer. The import rejected the function.Action: Fix your Simcenter Samcef model and import it again.Message: The functions must be the same for all the components of a Rotation Load. Only one function is imported.Explanation: For some loads defined by components, the function dependency must be the same for all components. The import replicated the function of the first component to all the others.Action: Fix your Simcenter 3D model, especially if the replicated functions modify the physics of your problem.Message: Fails to create expressionExplanation: The import could not convert a Simcenter Samcef analytical .FCT function to a valid Simcenter 3D expression. The function was ignored.In most cases, the analytical function uses an unsupported mathematical operator. For more information on imported math operators, see Importing functions to fields or expressions (Simcenter Samcef).Note: Conversion of analytical functions to expressions occurs only for loads and constraints. For other data (for example, materials), Simcenter Samcef analytical functions are not supported.Action: Fix your Simcenter 3D model. | Message: Error importing function : too many independent variables to create the table.Explanation: The import can only parse .FCT functions of two variables (U V) or fewer. The import rejected the function.Action: Fix your Simcenter Samcef model and import it again. | Message: The functions must be the same for all the components of a Rotation Load. Only one function is imported.Explanation: For some loads defined by components, the function dependency must be the same for all components. The import replicated the function of the first component to all the others.Action: Fix your Simcenter 3D model, especially if the replicated functions modify the physics of your problem. | Message: Fails to create expressionExplanation: The import could not convert a Simcenter Samcef analytical .FCT function to a valid Simcenter 3D expression. The function was ignored.In most cases, the analytical function uses an unsupported mathematical operator. For more information on imported math operators, see Importing functions to fields or expressions (Simcenter Samcef).Note: Conversion of analytical functions to expressions occurs only for loads and constraints. For other data (for example, materials), Simcenter Samcef analytical functions are not supported.Action: Fix your Simcenter 3D model. |
| Message: Error importing function : too many independent variables to create the table.Explanation: The import can only parse .FCT functions of two variables (U V) or fewer. The import rejected the function.Action: Fix your Simcenter Samcef model and import it again. | ||||
| Message: The functions must be the same for all the components of a Rotation Load. Only one function is imported.Explanation: For some loads defined by components, the function dependency must be the same for all components. The import replicated the function of the first component to all the others.Action: Fix your Simcenter 3D model, especially if the replicated functions modify the physics of your problem. | ||||
| Message: Fails to create expressionExplanation: The import could not convert a Simcenter Samcef analytical .FCT function to a valid Simcenter 3D expression. The function was ignored.In most cases, the analytical function uses an unsupported mathematical operator. For more information on imported math operators, see Importing functions to fields or expressions (Simcenter Samcef).Note: Conversion of analytical functions to expressions occurs only for loads and constraints. For other data (for example, materials), Simcenter Samcef analytical functions are not supported.Action: Fix your Simcenter 3D model. | ||||
| Warning | Message: Warning during import of the following function. Bounds are not taken into account for the independent variable in Simcenter 3D.Explanation: .FCT functions bounds (BORNES parameter) cannot be parsed and were ignored.Message: Warning during import of the following function. Functions must have different names. Function is skipped.Explanation: Simcenter Samcef allows the same names for different .FCT functions. Simcenter 3D does not allow this. The function was ignored. Other issues may be raised later.Message: Warning during import of function with two variables. Analytical or Piecewise not supportedExplanation: You can import only classical two-variable functions (of the types ABS + ORD or COUPLES). Analytical or piecewise functions are not supported in this context. The function was ignored. | Message: Warning during import of the following function. Bounds are not taken into account for the independent variable in Simcenter 3D.Explanation: .FCT functions bounds (BORNES parameter) cannot be parsed and were ignored. | Message: Warning during import of the following function. Functions must have different names. Function is skipped.Explanation: Simcenter Samcef allows the same names for different .FCT functions. Simcenter 3D does not allow this. The function was ignored. Other issues may be raised later. | Message: Warning during import of function with two variables. Analytical or Piecewise not supportedExplanation: You can import only classical two-variable functions (of the types ABS + ORD or COUPLES). Analytical or piecewise functions are not supported in this context. The function was ignored. |
| Message: Warning during import of the following function. Bounds are not taken into account for the independent variable in Simcenter 3D.Explanation: .FCT functions bounds (BORNES parameter) cannot be parsed and were ignored. | ||||
| Message: Warning during import of the following function. Functions must have different names. Function is skipped.Explanation: Simcenter Samcef allows the same names for different .FCT functions. Simcenter 3D does not allow this. The function was ignored. Other issues may be raised later. | ||||
| Message: Warning during import of function with two variables. Analytical or Piecewise not supportedExplanation: You can import only classical two-variable functions (of the types ABS + ORD or COUPLES). Analytical or piecewise functions are not supported in this context. The function was ignored. |
Issues related to importing solver and solution data
| Message type | Details | ||
|---|---|---|---|
| Error | Message: First occurrence of Subcase Parameter has been migrated to the Solution Parameters. The other occurrences are skipped."Explanation: The importer found several occurrences for a solution parameter common to .ALGO and .SUBCASE commands. Only the first occurrence was imported; the others were ignored.Action: Fix your Simcenter Samcef model by removing the extraneous occurrences and import it again.Message: Several .ALGO, .SAM or .GEL commands found in the datx file, not allowedExplanation: Several occurrences of the same Simcenter Samcef solution commands prevented the importer from determining the model solution.Action: Fix your Simcenter Samcef model by removing the redundant occurrences and import it again. | Message: First occurrence of Subcase Parameter has been migrated to the Solution Parameters. The other occurrences are skipped."Explanation: The importer found several occurrences for a solution parameter common to .ALGO and .SUBCASE commands. Only the first occurrence was imported; the others were ignored.Action: Fix your Simcenter Samcef model by removing the extraneous occurrences and import it again. | Message: Several .ALGO, .SAM or .GEL commands found in the datx file, not allowedExplanation: Several occurrences of the same Simcenter Samcef solution commands prevented the importer from determining the model solution.Action: Fix your Simcenter Samcef model by removing the redundant occurrences and import it again. |
| Message: First occurrence of Subcase Parameter has been migrated to the Solution Parameters. The other occurrences are skipped."Explanation: The importer found several occurrences for a solution parameter common to .ALGO and .SUBCASE commands. Only the first occurrence was imported; the others were ignored.Action: Fix your Simcenter Samcef model by removing the extraneous occurrences and import it again. | |||
| Message: Several .ALGO, .SAM or .GEL commands found in the datx file, not allowedExplanation: Several occurrences of the same Simcenter Samcef solution commands prevented the importer from determining the model solution.Action: Fix your Simcenter Samcef model by removing the redundant occurrences and import it again. | |||
| Info | Message: Automatic choice of the analysis and solution types has been activated, but no way to do a judicious choice. Default are chosen.Explanation: The importer could not determine the type of analysis in the imported model. | Message: Automatic choice of the analysis and solution types has been activated, but no way to do a judicious choice. Default are chosen.Explanation: The importer could not determine the type of analysis in the imported model. | |
| Message: Automatic choice of the analysis and solution types has been activated, but no way to do a judicious choice. Default are chosen.Explanation: The importer could not determine the type of analysis in the imported model. |
Issues related to importing Simcenter Samcef macros
Note:
The import stores Simcenter Samcef macro commands in simulation objects.
| Message type | Details | ||
|---|---|---|---|
| Error | Message: Error saving a simulation object : Failed to assign data to the first/second group.Explanation: The Simcenter Samcef groups referenced by the imported Simcenter Samcef macro command could not be found in regions, and the import failed to parse the macro data to build the missing regions. The import rejected the Simcenter Samcef macro command.Action: Check the Options tab in the Simcenter Samcef File Import dialog box to ensure that you import Simcenter Samcef groups. In addition, check your Simcenter Samcef model to see if the groups contain entities that are not supported by Simcenter 3D. If so, fix the model and import it again.Message: Fails to save target set. All elements must be of the same dimension.Explanation: One of the groups used by the imported Simcenter Samcef macro has a mix of 1D, 2D, or 3D elements. This problem can also occur for a group of edges or faces.Action: Fix your Simcenter Samcef model and import it again. | Message: Error saving a simulation object : Failed to assign data to the first/second group.Explanation: The Simcenter Samcef groups referenced by the imported Simcenter Samcef macro command could not be found in regions, and the import failed to parse the macro data to build the missing regions. The import rejected the Simcenter Samcef macro command.Action: Check the Options tab in the Simcenter Samcef File Import dialog box to ensure that you import Simcenter Samcef groups. In addition, check your Simcenter Samcef model to see if the groups contain entities that are not supported by Simcenter 3D. If so, fix the model and import it again. | Message: Fails to save target set. All elements must be of the same dimension.Explanation: One of the groups used by the imported Simcenter Samcef macro has a mix of 1D, 2D, or 3D elements. This problem can also occur for a group of edges or faces.Action: Fix your Simcenter Samcef model and import it again. |
| Message: Error saving a simulation object : Failed to assign data to the first/second group.Explanation: The Simcenter Samcef groups referenced by the imported Simcenter Samcef macro command could not be found in regions, and the import failed to parse the macro data to build the missing regions. The import rejected the Simcenter Samcef macro command.Action: Check the Options tab in the Simcenter Samcef File Import dialog box to ensure that you import Simcenter Samcef groups. In addition, check your Simcenter Samcef model to see if the groups contain entities that are not supported by Simcenter 3D. If so, fix the model and import it again. | |||
| Message: Fails to save target set. All elements must be of the same dimension.Explanation: One of the groups used by the imported Simcenter Samcef macro has a mix of 1D, 2D, or 3D elements. This problem can also occur for a group of edges or faces.Action: Fix your Simcenter Samcef model and import it again. | |||
| Warning | Message: Fails to set regions, trying an other way.Explanation: The Simcenter Samcef groups referenced by the imported Simcenter Samcef macro commands could not be found in the imported regions. The import parsed the macro data to build the missing regions.This message can also appear if you choose not to create regions in the Selection Options page of the Options tab in the Simcenter Samcef File Import dialog box (Custom menu).Action: Change the import options and import your Simcenter Samcef model again.Message: Unknown value for property:Explanation: A Simcenter Samcef macro parameter has an unsupported value. The import used a default value instead.Action: Check the simulation objects in your Simcenter 3D model. | Message: Fails to set regions, trying an other way.Explanation: The Simcenter Samcef groups referenced by the imported Simcenter Samcef macro commands could not be found in the imported regions. The import parsed the macro data to build the missing regions.This message can also appear if you choose not to create regions in the Selection Options page of the Options tab in the Simcenter Samcef File Import dialog box (Custom menu).Action: Change the import options and import your Simcenter Samcef model again. | Message: Unknown value for property:Explanation: A Simcenter Samcef macro parameter has an unsupported value. The import used a default value instead.Action: Check the simulation objects in your Simcenter 3D model. |
| Message: Fails to set regions, trying an other way.Explanation: The Simcenter Samcef groups referenced by the imported Simcenter Samcef macro commands could not be found in the imported regions. The import parsed the macro data to build the missing regions.This message can also appear if you choose not to create regions in the Selection Options page of the Options tab in the Simcenter Samcef File Import dialog box (Custom menu).Action: Change the import options and import your Simcenter Samcef model again. | |||
| Message: Unknown value for property:Explanation: A Simcenter Samcef macro parameter has an unsupported value. The import used a default value instead.Action: Check the simulation objects in your Simcenter 3D model. | |||
| Info | Message: The following parameters are unknown in Simcenter 3D. They are stored in the "User Defined Parameters" propertyExplanation: Unsupported Simcenter Samcef macro parameters are not stored in the User Defined Text epilog file, but rather in the User Defined Parameters of the Advanced Parameters page of the simulation object itself. | Message: The following parameters are unknown in Simcenter 3D. They are stored in the "User Defined Parameters" propertyExplanation: Unsupported Simcenter Samcef macro parameters are not stored in the User Defined Text epilog file, but rather in the User Defined Parameters of the Advanced Parameters page of the simulation object itself. | |
| Message: The following parameters are unknown in Simcenter 3D. They are stored in the "User Defined Parameters" propertyExplanation: Unsupported Simcenter Samcef macro parameters are not stored in the User Defined Text epilog file, but rather in the User Defined Parameters of the Advanced Parameters page of the simulation object itself. |
Issues related to importing units systems
| Message type | Details | ||
|---|---|---|---|
| Error | Message: The factor [factor] cannot be taken into account for the Unit [init]. SI unit system has been chosen by default - This option can be changed in the Import dialog.where [unit] is the name of the unit that cannot be imported and where [factor] is this unit factor in the Simcenter Samcef model.Explanation: One unit factor of the Simcenter Samcef .UNIT definition in the imported model does match any Simcenter 3D unit system. Therefore, the SI unit was selected.Action: In the Simcenter Samcef File Import dialog box, force a different unit system than the SI one and import the model again.Message: The temperature unit is unknown. Kelvin has been chosen by default.Explanation: If the temperature unit does not match any Simcenter 3D unit systems, the Kelvin unit is chosen. | Message: The factor [factor] cannot be taken into account for the Unit [init]. SI unit system has been chosen by default - This option can be changed in the Import dialog.where [unit] is the name of the unit that cannot be imported and where [factor] is this unit factor in the Simcenter Samcef model.Explanation: One unit factor of the Simcenter Samcef .UNIT definition in the imported model does match any Simcenter 3D unit system. Therefore, the SI unit was selected.Action: In the Simcenter Samcef File Import dialog box, force a different unit system than the SI one and import the model again. | Message: The temperature unit is unknown. Kelvin has been chosen by default.Explanation: If the temperature unit does not match any Simcenter 3D unit systems, the Kelvin unit is chosen. |
| Message: The factor [factor] cannot be taken into account for the Unit [init]. SI unit system has been chosen by default - This option can be changed in the Import dialog.where [unit] is the name of the unit that cannot be imported and where [factor] is this unit factor in the Simcenter Samcef model.Explanation: One unit factor of the Simcenter Samcef .UNIT definition in the imported model does match any Simcenter 3D unit system. Therefore, the SI unit was selected.Action: In the Simcenter Samcef File Import dialog box, force a different unit system than the SI one and import the model again. | |||
| Message: The temperature unit is unknown. Kelvin has been chosen by default.Explanation: If the temperature unit does not match any Simcenter 3D unit systems, the Kelvin unit is chosen. | |||
| Warning | Message: Unit defined in the imported bank is different than the unit selectedExplanation: In the Simcenter Samcef File Import dialog box, you forced a different unit system than the one found in the imported model. | Message: Unit defined in the imported bank is different than the unit selectedExplanation: In the Simcenter Samcef File Import dialog box, you forced a different unit system than the one found in the imported model. | |
| Message: Unit defined in the imported bank is different than the unit selectedExplanation: In the Simcenter Samcef File Import dialog box, you forced a different unit system than the one found in the imported model. | |||
| Info | Message: Unit defined in the imported bank is different than the unit selectedExplanation: In the Simcenter Samcef File Import dialog box, you forced a different unit system than the one found in the imported model.Message: The imported bank file is supposed to be defined with following units:Explanation: This is a reminder of the units system found in the imported model. | Message: Unit defined in the imported bank is different than the unit selectedExplanation: In the Simcenter Samcef File Import dialog box, you forced a different unit system than the one found in the imported model. | Message: The imported bank file is supposed to be defined with following units:Explanation: This is a reminder of the units system found in the imported model. |
| Message: Unit defined in the imported bank is different than the unit selectedExplanation: In the Simcenter Samcef File Import dialog box, you forced a different unit system than the one found in the imported model. | |||
| Message: The imported bank file is supposed to be defined with following units:Explanation: This is a reminder of the units system found in the imported model. |
Specific issues when appending and merging data from a Nastran input file
| Message type | Details | ||||
|---|---|---|---|---|---|
| Error | Message: Impossible to find %n element(s) in the current model. Following elements will not be updated.where %n indicates the number of not imported elements.Explanation: Some valid parsed elements in the Nastran input file do not exist in the current Simcenter Samcef model.Message: Impossible to add Element Associated Data for %n element(s) - Labels :.where %n indicates the number of elements.Explanation: For some parsed elements in the Nastran input file, the corresponding element in the current Simcenter Samcef model do not allow a Element Associated Data entry (for instance because the element is not 3D.Message: Impossible to find a material for %n element(s) - Labels id:.where %n indicates the number of elements.Explanation: Some parsed PSOLID bulk cards refer to a material that has not been imported.Message: Impossible to find a material orientation for %n element(s) - Labels id:.where %n indicates the number of elements.Explanation: Some parsed PSOLID bulk cards refer to a material orientation that has not been fetched during the import. | Message: Impossible to find %n element(s) in the current model. Following elements will not be updated.where %n indicates the number of not imported elements.Explanation: Some valid parsed elements in the Nastran input file do not exist in the current Simcenter Samcef model. | Message: Impossible to add Element Associated Data for %n element(s) - Labels :.where %n indicates the number of elements.Explanation: For some parsed elements in the Nastran input file, the corresponding element in the current Simcenter Samcef model do not allow a Element Associated Data entry (for instance because the element is not 3D. | Message: Impossible to find a material for %n element(s) - Labels id:.where %n indicates the number of elements.Explanation: Some parsed PSOLID bulk cards refer to a material that has not been imported. | Message: Impossible to find a material orientation for %n element(s) - Labels id:.where %n indicates the number of elements.Explanation: Some parsed PSOLID bulk cards refer to a material orientation that has not been fetched during the import. |
| Message: Impossible to find %n element(s) in the current model. Following elements will not be updated.where %n indicates the number of not imported elements.Explanation: Some valid parsed elements in the Nastran input file do not exist in the current Simcenter Samcef model. | |||||
| Message: Impossible to add Element Associated Data for %n element(s) - Labels :.where %n indicates the number of elements.Explanation: For some parsed elements in the Nastran input file, the corresponding element in the current Simcenter Samcef model do not allow a Element Associated Data entry (for instance because the element is not 3D. | |||||
| Message: Impossible to find a material for %n element(s) - Labels id:.where %n indicates the number of elements.Explanation: Some parsed PSOLID bulk cards refer to a material that has not been imported. | |||||
| Message: Impossible to find a material orientation for %n element(s) - Labels id:.where %n indicates the number of elements.Explanation: Some parsed PSOLID bulk cards refer to a material orientation that has not been fetched during the import. | |||||
| Warning | Message: The Append Merge Option can only be Add File Data and a material offset is used to overwrite existing materialsExplanation: You can only used the Add File Data option.Message: The Material offset %i is lower than greatest material number. Material offset is changed to %2Explanation: You manually set a wrong material label offset. | Message: The Append Merge Option can only be Add File Data and a material offset is used to overwrite existing materialsExplanation: You can only used the Add File Data option. | Message: The Material offset %i is lower than greatest material number. Material offset is changed to %2Explanation: You manually set a wrong material label offset. | ||
| Message: The Append Merge Option can only be Add File Data and a material offset is used to overwrite existing materialsExplanation: You can only used the Add File Data option. | |||||
| Message: The Material offset %i is lower than greatest material number. Material offset is changed to %2Explanation: You manually set a wrong material label offset. |
Look up more details
File Import dialog box (Simcenter Samcef)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Common issues when importing a model (Simcenter Samcef), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1362812 · retrieved 2026-07-17