When you open a model that contains old Thermal Void loads and that was saved in NX 10 or an older version, the software migrates:

  • Each old Thermal Void load to a new Void Region.

  • Old Void Non-Geometric Element modeling objects to new Thermal Void loads. The software may create multiple Thermal Void loads from a single Void Non-Geometric Element modeling object.

The software links the new Void Regions to appropriate new Thermal Void loads.

NX 10 or older version Current version
3 thermal voids 1 thermal void with 1 highlighted void region
GasTurbine_sim1.sim GasTurbine_fem1.fem CSYS Groups Fields Modeling Objects Void Non-Geometric Element1 Regions Simulation Object Container Constraint Container Load Container Solver Sets Solution 1 Simulation Objects Constraint Set Loads Thermal Void(1) Thermal Void(2) Thermal Void(3) Results GasTurbine_sim1.sim GasTurbine_fem1.fem CSYS Groups Fields Modeling Objects Void Non-Geometric Element1 Regions Simulation Object Container Constraint Container Load Container Solver Sets Solution 1 Simulation Objects Constraint Set Loads Thermal Void(1) Thermal Void(2) Thermal Void(3) Results GasTurbine_sim1.sim GasTurbine_fem1.fem CSYS Groups Fields Modeling Objects Regions 1 - Thermal Void(1) Region1 2 - Thermal Void(2) Region1 3 - Thermal Void(3) Region1 Simulation Object Container Constraint Container Load Container Solver Sets Solution 1 Simulation Objects Constraint Set Loads V1 Results GasTurbine_sim1.sim GasTurbine_fem1.fem CSYS Groups Fields Modeling Objects Regions 1 - Thermal Void(1) Region1 2 - Thermal Void(2) Region1 3 - Thermal Void(3) Region1 Simulation Object Container Constraint Container Load Container Solver Sets Solution 1 Simulation Objects Constraint Set Loads V1 Results
GasTurbine_sim1.sim
GasTurbine_fem1.fem
CSYS
Groups
Fields
Modeling Objects
Void Non-Geometric Element1
Regions
Simulation Object Container
Constraint Container
Load Container
Solver Sets
Solution 1
Simulation Objects
Constraint Set
Loads
Thermal Void(1)
Thermal Void(2)
Thermal Void(3)
Results
GasTurbine_sim1.sim
GasTurbine_fem1.fem
CSYS
Groups
Fields
Modeling Objects
Regions
1 - Thermal Void(1) Region1
2 - Thermal Void(2) Region1
3 - Thermal Void(3) Region1
Simulation Object Container
Constraint Container
Load Container
Solver Sets
Solution 1
Simulation Objects
Constraint Set
Loads
V1
Results

If the old model contains VA(), VP(), VSV(), or VT() functions in boundary condition expressions that reference the old Thermal Void load, you need to correct each function to reference the appropriate new Thermal Void load and, optionally, the region of interest. These old expressions are preserved as comments in their respective fields and those fields now return a value of 1. You can modify the commented expressions directly from their respective fields or in the Expressions dialog box.

How do I

Create a Thermal Void load

Learn more

Thermal Void

Inputs to expressions

Displaying data summary in HTML

Look up more details

Auto-generated expressions

HTML summary data

Quick links

Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions

Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Migration of models with old Thermal Void loads, Simcenter 3D 2021.1 Series