SimcenterKnowledge

Command reference help topics

Chocking Property dialog box (Multiphysics)

Physical Property Table
Name Defines the name of the physical property table.
Label Defines the unique numeric identifier for the physical property table.
Properties
Material Lets you assign either an isotropic (MAT1) or an orthotropic (MAT11) material to the elements. Select a material from the list of materials assigned to the model, or click Choose material to define a new material.
Number of Gaps Sets the number of gaps around the circumference.
Gap Thickness Sets the gap thickness.
Thermo-Optical Properties
Radiation Activates radiation calculations for the elements in the mesh collector.
Thermo-Optical Properties Defines the emissivity for modeling radiation. Black Body Defines an emissivity of 1. Thermo-Optical Properties Defines a constant or temperature-varying emissivity. Thermo-Optical Properties-Advanced Defines the infrared and solar thermo-optical properties for modeling gray radiation or wavelength-dependent thermo-optical properties for modeling non-gray radiation. Select Black Body or a modeling object from the list, or click Create Modeling Object to define a new modeling object. Click Edit to modify the specified modeling object. Click More Options to search and filter regions. The following options are available. Find Lets you search for an object by entering the full name of the object. For example, to find a region named ABC_region, type ABC_region in the search box and press Enter or click Find . If the object is found, it will be selected automatically. Filter by Name Lets you filter the list by the names of the objects. This filter supports wildcards. The default wildcard is the asterisk (), and it displays all entries in the list. For example, to filter the list to display every object with a name starting with the letter “a," enter a as the filter string.
Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Chocking elements

Fourier harmonics analysis

Specifying harmonic index numbers

Axisymmetric Fourier harmonics post-processing options

Chocking Property dialog box (Multiphysics), Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1124991 · retrieved 2026-07-17