FE Model Correlation and Update > Correlation solution process > Correlate
Display COMAC results in Post Processing
To display COMAC results mode pairs must exist. Make sure that the number in square brackets of the Mode Pairs [#] node in the Simulation Navigator is not zero.
In the Simulation Navigator, right-click the Mode Correlation Metrics node under the Correlation node and select (1 – COMAC).The (1 – COMAC) node is generated under the Mode Correlation Metrics node. Mode Correlation Metrics (1 – COMAC)
Right-click the (1 – COMAC) node and select Open.The generated (1 – COMAC) results are loaded in the Post Processing Navigator.In a structural shape correlation solution processes, the generated (1 – COMAC) can include up to three coordinate components. Correlation 1 (1 – COMAC), X Component – Nodal (1 – COMAC), Y Component – Nodal Scalar (1 – COMAC), Z Component – NodalIn acoustic shape correlation solution processes, the generated (1 – COMAC) includes a single scalar component. Correlation 2 (1 – COMAC), X Component – Nodal Scalar
In the Post Processing Navigator, double click the (1 – COMAC), Y Component – Nodal node to display the (1 – COMAC) results for the Y component of structural shape correlation.The results displayed are (1 – COMAC) values at each translational degree-of-freedom, and not COMAC values. Thus, values approaching 1.0 indicate that these degrees-of-freedom have poor correlation across the set of paired mode shapes.
How do I
Display correlation metrics as 2D matrix plots
Edit 2D matrix plot display
Export correlation metric results
Plot mode shapes of the work and reference solutions
Display the MAC Contribution results
Display overlay FRFs at specified stretch parameter
Learn more
Correlation metrics
MAC Contribution
MODMAC Evolution
FRF pair XY plots
FRAC plots
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Display COMAC results in Post Processing, Simcenter 3D 2021.1 Series