Orphan load cases (load case filtering)

Load case filtering solutions create links to results they use. Therefore, if you rename or delete subcases that the load case filtering solution uses as load cases, and you rerun the solution, the links break and the software can no longer access the results it needs to filter load cases. Such load cases are referred to as orphan load cases.

Detecting orphan load cases

The first clue that an orphan load case may exist is the lack of a load case filtering result in the Load Case Filtering Results dialog box, in the Load Case Filtering table. To verify that an orphan load case exists, in the Load Cases Editor dialog box, display the Orphan column. A selected check box in the Orphan column indicates that the corresponding load case is an orphan load case.

Removing orphan load cases

When an orphan load case exists, in the Load Cases Editor dialog box, the Clean up orphaned load cases command appears. When you select this command, the software does the following:

  • Removes renamed subcases from any load case sets for which they are a member. The software retains the renamed load case so that under its new name you can add it back into the load case sets from which it was removed, or you can add it to other load case sets.

  • Removes all deleted subcases in the load case filtering solution.

Where do I find it?

Application Pre/Post
Prerequisite An active load case filtering solution
Simulation Navigator Right-click the load case filtering solution→Edit Load Cases
How do I

Create a combined load case

Modify combined load cases in a dialog box

Modify combined load cases in a spreadsheet or text editor

Create a load case set for a load case filtering calculation

Create a load case set from load case filtering results

Learn more

Load case sets (load case filtering)

Combined load cases

Results for combined load cases

Exporting and importing load case sets (load case filtering)

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Load Case Filtering method documentation

Orphan load cases (load case filtering), Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1924748 · retrieved 2026-07-17