Boundary conditions > Solver sets > Load sets
Frequency Excitation Set
Use a Frequency Excitation Set to define a frequency-dependent dynamic load for use in a frequency response analysis.
You can define the value of the excitation as a function of frequency, using any of the following:
A complex expression
A magnitude and phase expression
A field
You can also define dynamic load phase leads and time delay in the Frequency Excitation Set dialog box.
Adding loads to a Frequency Excitation Set
You cannot add individual loads to a dynamic load set, but you can add a static load set, and add individual loads to that.
You can add an Applied Load type of static load set only to a frequency excitation load set of type Applied Load.
You can add an Enforced Motion type of static load set only to a frequency excitation load set of type Enforced Displacement, Enforced Velocity, or Enforced Acceleration. The type of motion created by an Enforced Motion Load is specified by the type of frequency excitation load set into which you place the static load.
You can add an Enforced Acoustic Pressure type of static load set only to a frequency excitation load set of type Enforced Acoustic Pressure.
Adding a static load set to a Frequency Excitation Set
When the Automatic Creation check box is selected, the software automatically creates an empty Load Set (General) and adds it to the Frequency Excitation Set.
When the Automatic Creation check box is cleared, you can choose a static load set from the list, or choose None and create your own, empty Load Set (General).
Corresponding Nastran Syntax
The Frequency Excitation Set corresponds to the Simcenter Nastran RLOAD1 bulk entry.
The Label field in the Frequency Excitation Set dialog box assigns the SID or load set identification number for Simcenter Nastran.
Where do I find it?
| Application | Pre/Post |
|---|---|
| Prerequisite | Simcenter Nastran, MSC Nastran, or Simcenter 3D Multiphysics as the specified solver |
| Simulation Navigator | Right-click Solver Sets→New→Frequency Excitation Set |
How do I
Create a load set
Add a load to a load set
Learn more
Load sets
Load Set (General)
Acoustic Load Set
Acoustic Source Load Set (Legacy)
Transient Excitation Set
Bolt Load Set
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Frequency Excitation Set, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid917286 · retrieved 2026-07-17