SimcenterKnowledge

Command reference help topics

Panel Ray Source dialog box

Name
Name Specifies the name of the panel ray source.
Description Specifies the description for the panel ray source.
Destination Folder
Simulation Object Container Specifies the folder in the Simulation Navigator in which to store the acoustic panel ray source.The list includes the root container and folders that you created using the New Folder command in the Simulation Object Container.
Folder Manager Displays a hierarchical list of folders.To create a new folder, right-click any level of the hierarchy and choose New Folder.
Model Objects
Defines the support for the panel ray source. You can select faces of 2D fluid elements or refer to an existing group that contains faces of 2D fluid elements.
Elements to Create Panel Ray Source On Lets you select faces of 2D fluid elements for the panel ray source.
Group Reference Lets you select the groups of free faces of fluid elements to apply a panel ray source.For more information, see Group Reference options.
Select Object Lets you select the FE entities on which to apply the panel ray source.Excluded:Lets you remove individual entities from within the selected object.
Stacked Smart Selector Methods Opens the Smart Selector Methods dialog box where you can specify a progression of smart selection filters.For more information, see Smart Selector Methods dialog box.
Magnitude
Specifies the constant complex excitation with real and imaginary parts, constant complex excitation with magnitude and phase angle, or the frequency-dependent complex field values.
Magnitude Type Sets the type of magnitude. You can choose Power, Pressure, or Intensity.
Power in dB Appears when Magnitude Type is set to Power.Lets you enter Real/Imaginary, Magnitude/Phase, or Field values in dB with respect to the standard power reference (1.E-12 Watt).
Pressure in dB Appears when Magnitude Type is set to Pressure.Lets you enter Real/Imaginary, Magnitude/Phase, or Field values in dB with respect to the standard pressure reference (2.E-5 Pascal).
Intensity in dB Appears when Magnitude Type is set to Intensity.Lets you enter Real/Imaginary, Magnitude/Phase, or Field values in dB with respect to the standard intensity reference (1.E-12 Watt/m2).
Real Appears when Power, Pressure, or Intensity is set to Real/Imaginary.Sets the real component value of the selected magnitude type.
Imaginary Appears when Power, Pressure, or Intensity is set to Real/Imaginary.Sets the imaginary component value of the selected magnitude type.
Magnitude Appears when Power, Pressure, or Intensity is set to Magnitude/Phase.Sets the magnitude value of the selected magnitude type.
Phase Appears when Power, Pressure, or Intensity is set to Magnitude/Phase.Sets the phase angle value of the selected magnitude type.
Specify Field Appears when Power, Pressure, or Intensity is set to Field.Specifies the frequency-dependent complex field values.For information about included options, see Additional magnitude options.
Scale Factor Appears when Power, Pressure, or Intensity is set to Field.Sets the scaling of values present in the field.
Direction
Reverse Source Orientation When the Reverse Source Orientation check box is selected, the software reverses the direction of the source.
Show direction of orientation vectors Displays the orientation of the source.
Time Delay
Enable Time Delay Defines the time delay of the panel ray source.
Value Appears when the Enable Time Delay check box is selected.Sets the constant time delay value. For more information, see Additional magnitude options.
Learn more

Simcenter 3D Ray Acoustics environment

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Panel Ray Source dialog box, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1761877 · retrieved 2026-07-17