After you run an analysis, you can rewrite the results file, select additional result sets, and rewrite the results or report files.

Note:

For a thermal or coupled thermal-flow analysis, in your initial run, you need to select the Output Files for Refresh Results / Refresh Reports check box on the Results Options page in the Solution dialog box so that the thermal solver generates the necessary files for refreshing results and reports.

  1. In the Simulation Navigator, right-click the Results node and choose Delete.

  2. Right-click the Solution node and choose Edit.

  3. In the Solution dialog box, click the Results Options page.

  4. Expand each results group and select additional result sets.

  5. Expand the Control group.

  6. Click Refresh Results or Refresh Reports.

  7. Click OK.

How do I

Inspect intermediate results

Continue a transient solution

Restart a steady state solution

Reuse thermal solution data in a modified or different solution

Specify a flow user defined API file

Create or modify a solution

Learn more

Solving the model

Solution Monitor

Solution Control Monitor

Displaying data summary in HTML

Parallel processing

TMG Executive Menu

Customizing thermal and flow solvers through API

Look up more details

Effective program limits

Converged analysis

HTML summary data

Verbose thermal solver messaging

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions

Refresh results and reports in a solution, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id919974 · retrieved 2026-07-17