Samcef environment > Samcef output requests
Time history graphs: element results (Simcenter Samcef structural nonlinear)
In a Simcenter Samcef nonlinear analysis, you can use Non-linear Output Requests Element 9xxx modeling objects to output the following time history results graphs on elements:
Categories
Stress
| Sub Category | Simcenter Samcef codes |
|---|---|
| Stress Tensor (*) | Shells: 9470, 9472, 9471Other elements: 9411 |
| Normal Stress on beams section | 9440 |
| Shear Stress on beams sections | 9450 |
| Equivalent Gauss Points Stress (*) | Shells: 9390, 9392, 9391Other elements: 9310 |
Composite Stress
| Sub Category | Simcenter Samcef codes |
|---|---|
| Stress Tensor | Shells: 19411, 29411, 9411Other elements: 9411 |
| Interlaminar Stress Tensor | 9413 |
Strain
| Sub Category | Simcenter Samcef codes |
|---|---|
| Plastic Strain Tensor | Shells: 19425, 29425, 9425Volumes: 9425 |
| Total Strain Tensor | Shells: 9446, 9445Volumes: 9421 |
| Equivalent Cumulative Plastic Strain Tensor | Shells: 9380, 9382, 9381Volumes: 9320 |
Composite Strain
| Sub Category | Simcenter Samcef codes |
|---|---|
| Total Strain Tensor | Shells: 19421, 29421, 9421Volumes: 9421 |
Composite Criteria
For more details, see Composite criteria results codes in structural analyses (Simcenter Samcef).
Tensor Damage
| Sub Category | Simcenter Samcef codes |
|---|---|
| Tensor Damage | 9456 |
Scalar Damage
| Sub Category | Simcenter Samcef codes |
|---|---|
| Scalar Damage | Shells: 19356, 29356, 9356Volumes: 9356 |
Energy
| Sub Category | Simcenter Samcef codes |
|---|---|
| Potential Energy | 9334 |
Miscellaneous
| Result | Simcenter Samcef codes |
|---|---|
| Relative Displacements | 9530 |
Thermal Strain
| Result | Simcenter Samcef codes |
|---|---|
| Thermal Strain Tensor | 9422 |
Gasket
| Sub Category | Simcenter Samcef codes |
|---|---|
| Yield Stress | 9485 |
| Status | 9486 |
For tensor results, you can use the DOFS property to select components of the tensor. See Degrees of freedom below.
For shell-based results, you can use the Location list to select the shell location to which the result applies. See Location below.
User
For information, see User-defined time history graph results.
Categories and sub-categories
Use the Category list and the Sub Category list to select the result you want to define.
Degrees of freedom
For tensor results, you can define the components of the result to be output. For instance, you can only request the first component of a stress tensor. The components refer to the element's material axes.
Location
For shell results, you can use the Location list to choose between the Midplane, the Lower Skin, the Upper Skin, or All the shell positions:
Lower Skin
Only select the lower skin version of the result.
Upper Skin
Only select the upper skin version of the result.
Midplane
Only select the midplane version of the result.
All
Select all the positions in the shell.
For other elements, from the Location list, select Other elements.
Elements Selection
In the Select Elements group, select the elements to which you want to attach the result.
Where do I find it?
| Application | Pre/Post |
|---|---|
| Prerequisite | A Simulation file as the work part and displayed partSimcenter Samcef as the specified solverA nonlinear analysis as the active solution |
| Command Finder | Modeling Objects |
| Location in dialog box | Type list→Non-linear Output Requests Element 9xxx |
Look up more details
Time history output request manager dialog boxes (Simcenter Samcef)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Time history graphs: element results (Simcenter Samcef structural nonlinear), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1124045 · retrieved 2026-07-17