  1. In the Simulation Navigator, right-click the Model Update node and choose Edit.The Model Update dialog box opens.

  2. (Optional) Change the name of the Model Update solution process.

  3. In the Subcase Selection group, select a subcase for the work solution, and a subcase for the analysis reference solution.

  4. From the Measurement Type list, select Displacement.

  5. (Optional) Enter a value in the Cutoff Frequency (Hz) box to exclude low frequency modes with a frequency that is below the value that you specify.

  6. (Optional) Clear the Exclude Low-Frequency Modes check box if you want to include low frequency modes.

  7. (Optional) Select the Exclude High-Frequency Modes check box if you want to exclude modes with a frequency above the Cutoff Frequency (Hz) that you specify.

  8. In the Node Matching Tolerance box, type the matching tolerance value that the software will use for node to node pairing between work and reference solutions.

  9. Click OK.

How do I

Create a Model Update solution process

Learn more

Model update solution process

Work solution for the model update solution process

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Edit the Model Update solution process, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id1001357 · retrieved 2026-07-17