Samcef environment > Samcef solutions and analyses > Chaining solutions (Simcenter Samcef)
Chaining with a linear static solution (Simcenter Samcef)
You can chain a Linear Static active solution with several other solved solutions. In the solution's Chaining page, you select the solved solution you want to chain with and define the chaining parameters.
| Option | Description |
|---|---|
| Activate Chaining | Activates chaining. |
| Chaining Type | Specifies the chaining type:Static pre-stress—Performs a Linear Static solution with pre-stress conditions.Static with centrifugal stiffness—Performs a Linear Static solution with centrifugal stiffness computation.Static with initial imperfection—Performs a Linear Static solution with initial imperfection condition.Chained thermal-structural analysis—Performs a classic Heat Transfer - Linear Static chaining.Chained thermal-structural analysis with dissimilar mesh—Performs a Linear Static solution after a Mapping solution. |
| Source Type | Lets you select a Solution already defined in the current model to chain with, or an External File Simcenter Samcef binary file (.u18) to extract chaining data from. |
Static pre-stress chaining type
The Static pre-stress chaining type chains two linear static analyses. In the active linear static solution, you select the previous linear solution's load case from which you want to retrieve the pre-stress data.
| Option | Description |
|---|---|
| ***_as.u18 File** | Available when you select External File from the Source Type list.Lets you select the Simcenter Samcef binary linear static results file to use as source for stresses. For more details, see the IFPR FILE parameters of the .SAM Samcef command. |
| Load Case Number | Lets you select the load case number from which you want to retrieve the stresses. For more details, see the NPR parameter of the .SAM Samcef command. |
| Chaining with Solution | Available when you select Solution from the Source Type list.Lets you select in the linear static solution and the load case you want to chain with. |
Static with centrifugal stiffness chaining type
The Static with centrifugal stiffness chaining type chains two linear static analyses. In the active linear static solution, you select the previous linear solution's load case from which you want to retrieve the centrifugal stiffness.
| Option | Description |
|---|---|
| ***_as.u18 File** | Available when you select External File from the Source Type list.Lets you select the Simcenter Samcef binary linear static results file to use as source for the centrifugal stiffness. For more details, see the IFPR FILE parameters of the .SAM Samcef command. |
| Load Case Number | Lets you select the load case number from which you want to retrieve stiffness. For more details, see the NPR parameter of the .SAM Samcef command. |
| Chaining with Solution | Available when you select Solution from the Source Type list.Lets you select in the linear static solution and the load case you want to chain with. |
Static with initial imperfection chaining type
The Static with initial imperfection chaining type chains a buckling analysis with a linear static one. The linear static active solution uses one of the computed buckling modes as the initial imperfection condition for the linear static solving.
| Option | Description |
|---|---|
| Mode Shape Number | Lets you select the buckling mode to take into account in the chaining. For more details, see the NDEF parameter of the .SAM Samcef command. |
| Mode Shape Amplitude | Lets you define the mode shape amplitude to apply to this buckling mode. For more details, see the ADEF parameter of the .GEL Samcef command. |
| Chaining with Solution | Available when you select Solution from the Source Type list.Lets you select the buckling solution you want to chain with. |
| ***_st.u18 File** | Available when you select External File from the Source Type list.Lets you select the Simcenter Samcef binary buckling results file to use as source. For more details, see the IFDEF FILE parameters of the .SAM Samcef command. |
Chained thermal-structural analysis chaining type
The Chained thermal-structural analysis chaining type chains a thermal analysis with a static linear one. In the active linear static solution, you select the reference time at which the nodal temperatures must be retrieved from the thermal solution. These temperatures become thermal loads.
| Option | Description |
|---|---|
| Selected Time | Lets you select the time at which you want to retrieve the thermal results. For more details, see the TIME parameter of the .GEL Samcef command.Note: The real time from which thermal results are retrieved is the thermal computing (and archiving) time which is the nearest to the given Selected Time. |
| Chaining with Solution | Available when you select Solution from the Source Type list.Lets you select the thermal solution you want to chain with. |
| ***_mt.u18 File** | Available when you select External File from the Source Type list.Lets you select the Simcenter Samcef binary thermal results file to use as source. For more details, see the IUN FILE parameters of the .SAM Samcef command. |
Chained thermal-structural analysis with dissimilar mesh chaining type
The Chained thermal-structural analysis with dissimilar mesh chaining type chains a mapping solution with a linear static one. In the active linear static solution, you select the reference time at which the nodal temperatures (or the degree of cure values or the glass transition temperatures) have to be retrieved from the thermal solution. These results become thermal loads.
| Option | Description |
|---|---|
| Selected Time | Lets you select the time at which you want to retrieve the thermal results. For more details, see the TIME parameter of the .GEL Samcef command.Note: The real time from which thermal results are retrieved is the thermal computing (and archiving) time which is the nearest to the given Selected Time. |
| Chaining with Solution | Available when you select Solution from the Source Type list.Lets you select the mapping solution you want to chain with. |
| ***.txt File** | Available when you select External File from the Source Type list.Lets you select the mapping results text file to use as source. |
Look up more details
Solution dialog box (Simcenter Samcef Linear Static Analysis)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Chaining with a linear static solution (Simcenter Samcef), Simcenter 3D 2021.1 Series