SimcenterKnowledge

Command reference help topics

Frequency Response Solution Options dialog box

For more information about the options in this dialog box, see the SLVCNTL bulk data entry in the Simcenter Nastran Quick Reference Guide.

Modeling Object
Name Defines the name of the modeling object.
Label Specifies a unique numerical identifier for the modeling object.
Properties
Description Lets you enter a description for the frequency response solution options.
Unsymmetric Solver (USOLVER) Specifies the solver for the unsymmetric computations.
Symmetric Solver (SOLVER) Specifies the solver for the symmetric computations.
Pivoting Threshold Exponent Value (PTHRESH) Applicable when PARDISO is specified as the Unsymmetric Solver or Symmetric Solver.Sets the exponent value for the pivoting threshold.
Solver Output Messages (MSGLVL) Applicable when PARDISO or MUMPS is specified as the Unsymmetric Solver or Symmetric Solver.Specifies how messages are output from the solver.Pardiso Messages to .log FileWhen Pardiso is the specified solver, messages are output to the .log file.No Pardiso Messages to .log FileWhen Pardiso is the specified solver, no messages are output to the .log file.MUMPS Error messages to .f06 FileWhen MUMPS is the specified solver, error messages are output to the .f06 file.MUMPS Error messages to .f06 File, Warnings and Main Statistics to .f04 FileWhen MUMPS is the specified solver, error messages are output to the .f06 file. Warnings and main statistics are printed to the .f04 files.MUMPS Error messages to .f06 File, Warnings and Terse Diagnostics to .f04 FileWhen MUMPS is the specified solver, error messages are output to the .f06 file. For warnings and terse diagnostics, the first ten entries of arrays are printed to the .f04 files.MUMPS Error messages to .f06 File, Warnings and Parameters to .f04 FileWhen MUMPS is the specified solver, error messages are output to the .f06 file. For warnings and parameters, the first ten entries of arrays are printed to the .f04 files.
Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Frequency Response Solution Options dialog box, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1762255 · retrieved 2026-07-17