SimcenterKnowledge

Acoustics and vibro-acoustics > Simcenter Nastran FEM acoustics > Modeling fluid-structure coupling and interaction

Define fluid-structure interaction control parameters (Simcenter Nastran FEM acoustics)

  1. Choose Home tab → Properties group → Modeling Objects .Alternatively, click Create Modeling Object in the Case Control tab of the vibro-acoustic Solution dialog box.

  2. In the Modeling Objects Manager dialog box, from the Type list, select Fluid-Structure Interaction Control Parameters.

  3. Click Create.

  4. In the Fluid-Structure Interaction Control Parameters dialog box, in the Reference Pressure (PREFDB) box, enter the reference pressure value and select the units from the list.For more information, see Fluid-Structure Interaction Control Parameters dialog box (Nastran).

  5. From the Coupled Information (SKINOUT) list, select the appropriate parameters.Note: Depending on the selected Coupled Information (SKINOUT) parameters, you can view the coupling information and coupling quality results in post processing.

  6. Click OK to close the Fluid-Structure Interaction Control Parameters dialog box.The defined fluid-structure interaction control parameter appears in the Selection group table of the Modeling Object Manager.

  7. (Optional) Repeat steps 2-6 to define additional fluid-structure interaction control parameters.

  8. Click Close to complete the control parameter definition and close the Modeling Object Manager dialog box.

Add the defined fluid-structure interaction control parameter to the solution

  1. Right-click an active vibro-acoustic solution and choose Edit.

  2. In the Solution dialog box, click the Case Control page, from theFluid-Structure Interaction Control Parameters list, select the appropriate fluid-structure interaction control parameter.

  3. Click OK to close the Solution dialog box.

How do I

Define fluid-structure interface modeling parameters

Plot coupling quality results

Learn more

One-way fluid-structure interface coupling

Fluid-Structure Interaction Control Parameters dialog box (Nastran)

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Define fluid-structure interaction control parameters (Simcenter Nastran FEM acoustics), Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid951443 · retrieved 2026-07-17