Name
Name Sets the name for the acoustic temperature mapping simulation object.
Description Sets the description for the acoustic temperature mapping simulation object. This description appears in the Simulation Navigator.
Destination Folder
Simulation Object Container Specifies the folder in the Simulation Navigator in which to store the acoustic temperature mapping simulation object.The list includes the root container and folders that you created using the New Folder command in the Simulation Object Container.
Folder Manager Displays a hierarchical list of folders.To create a new folder, right-click any level of the hierarchy and choose New Folder.
Fluid Material Values
First Data Type Specifies whether the first data set to retrieve from the SCH5 file is mapped temperature or mapped speed of sound.
Second Data Type Specifies whether the second data set to retrieve from the SCH5 file is mapped mass density, mapped pressure, or constant pressure.
Data Source
Infers Relative Path Use the Mapped File box to manually specify the SCH5 file directory path.The software infers and stores the path to the file that you specify relative to the Simulation file. If the location of the file changes, the software uses the stored relative path information to try to locate the file. For more information, see Relative path support for external files.
Browse Opens the Mapped File dialog box.
First Data Set Specifies the name for the data set in the SCH5 file whose type matches the data type that you selected from the First Data Type list and whose data you want to use in the acoustic analysis.If you are unsure of the name, in the Simulation Navigator, right-click the input file name node→Edit. The names that you can specify are listed in the Model and Load Pre-processing dialog box, in the Target Storage Name column.Note: Target storage names are case sensitive.
Second Data Set Appears when Second Data Type is set to Mapped Mass Density or Mapped Pressure.Specifies the name for the data set in the SCH5 file whose type matches the data type that you selected from the Second Data Type list and whose data you want to use in the acoustic analysis.If you are unsure of the name, in the Simulation Navigator, right-click the input file name node→Edit. The names are listed in the Model and Load Pre-processing dialog box, in the Target Storage Name column.Note: Target storage names are case sensitive.
Constant Pressure Appears when Second Data Type is set to Constant Pressure.Specifies the pressure to use in the acoustic analysis.
Infer Data Sets Finds the data sets in the SCH5 file that match the data types that you selected from the First Data Type and Second Data Type lists.If the SCH5 file contains multiple data sets for the specified type, the software selects the first data set of that type in the Data list in the Model and Load Pre-processing dialog box.Tip: If you do not want the data set that the software selects, override the selection by typing the name of the data set that you do want in the First Data Set or Second Data Set boxes.
Fluid Properties
Adiabatic Index (Gamma) Specifies the adiabatic index for the fluid.
Specific Gas Constant (R) Specifies the gas constant for the fluid.
Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Acoustic Temperature Mapping dialog box, Simcenter 3D 2021.1 Series

© 2020 Siemens

window.mainLanguage="en_US"

window.delivId=""

window.projectId=""

MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });

Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1597210 · retrieved 2026-07-17