| Name | |
|---|---|
| Name | Sets the name of the constraint. |
| Description | Sets the description for the constraint. |
| Destination Folder | |
| Load Container | Specifies the folder in the Simulation Navigator in which to store the acoustic panel normal velocity boundary condition.The list includes the root container and folders that you created using the New Folder command in the Load Container. |
| Folder Manager | Displays a hierarchical list of folders.To create a new folder, right-click any level of the hierarchy and choose New Folder. |
| Nodes | |
| Group Reference | Lets you select a group of nodes of the acoustic fluid mesh to apply the enforced velocity.For more information, see Group Reference options. |
| Select Object | Specifies the nodes of the acoustic fluid mesh to which to apply the enforced velocity. |
| Stacked Smart Selector Methods | Opens the Smart Selector Methods dialog box where you can specify a progression of smart selection filters.For more information, see Smart Selector Methods dialog box. |
| Excluded | Lets you remove individual entities from within the selected object. |
| Value | |
| Specifies the complex excitation values as real and imaginary parts, magnitude and phase angle, and complex field values of the enforced velocity. | |
| Enforced Velocity | Specifies how the excitation is defined. |
| Real | Available when Enforced Velocity is set to Real/Imaginary.Sets the real component value of the magnitude of the excitation. |
| Imaginary | Available when Enforced Velocity is set to Real/Imaginary.Sets the imaginary component value of the magnitude of the excitation. |
| Magnitude | Available when Enforced Velocity is set to Magnitude/Phase.Sets the magnitude value of the excitation. |
| Phase | Available when Enforced Velocity is set to Magnitude/Phase.Sets the phase angle value of the excitation. |
| Specify Field | Available when Enforced Velocity is set to Field.Specifies the frequency-dependent complex field values. For more information, see Additional magnitude options. |
Learn more
Simcenter 3D Noise and Vibration environment
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Enforced Velocity Constraint dialog box (Noise and Vibration), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1939053 · retrieved 2026-07-17