Flow Boundary Condition dialog box – Static Pressure options
| Name | |
|---|---|
| Name | Sets a name for the simulation object.Description opens an editor that lets you type a description for the boundary condition. |
| Destination Folder | |
| Simulation Object Container | Specifies the folder in the Simulation Navigator in which the boundary condition will be stored. The list includes the root container and existing folders that you created using the New Folder command. Examples of a root container include Load Container, Constraint Container, and Simulation Object Container. |
| Folder Manager | Displays a hierarchical listing of existing folders. To create a new folder, right-click any level of the hierarchy and choose New Folder. |
| Region | |
| Group Reference | Applies the static pressure boundary condition to the selected group. For more information, see Group Reference options. |
| Select Object | Lets you select the faces or elements on the boundary of the flow domain to which you specify the static pressure.Excluded lets you remove individual entities from within your selected object. The software does not apply the simulation object to the excluded elements.Note: The Element Selection Filtering options are available when the Type Filter list on the Top Border bar is set to Elements. |
| Stacked Smart Selector Methods | Opens the Smart Selector Methods dialog box where you can specify a progression of smart selection filters.For more information, see Smart Selector Methods dialog box. |
| External Conditions | |
| External Conditions | Specifies the temperature, humidity, and turbulence characteristics at the boundary.AmbientSpecifies ambient flow conditions at the boundary, which you define on the Ambient Conditions page of the Solution dialog box.External Conditions modeling objectSpecifies the flow conditions at the boundary through the selected External Conditions modeling object.You can also select a previously defined External Conditions modeling object from the list or click Create Modeling Object to define a new modeling object.Click Edit to modify the specified modeling object. |
| Turbulence Characteristics | Specifies which method is used to specify turbulence properties of fluid based on available data derived from experiment or standard references.AutomaticLets the solver compute automatically turbulence characteristics.Turbulence Characteristics modeling objectSpecifies the method for calculation initial turbulence quantities through the selected Turbulence Characteristics modeling object.You can also select a previously defined Turbulence Characteristics modeling object from the list or click Create Modeling Object to define a new modeling object.Click Edit to modify the specified modeling object.For more information, see Turbulence Characteristics. |
| External Pressure Type | Specifies whether the static pressure is absolute or relative to ambient pressure. |
| External Absolute Pressure | Appears when External Pressure Type is set to Absolute.Specifies the absolute static pressure at the selected element.AmbientDefines the external absolute pressure to the value that you set on the Ambient Conditions page of the Solution dialog box.SpecifyDefines a constant external absolute pressure or a time-varying external absolute pressure. You set the value in the Pressure Value box. |
| External Relative Pressure | Appears when External Pressure Type is set to Relative.Specifies a constant relative static pressure or a time-varying relative static pressure. You set the value in the External Relative Pressure box. For more information, see Additional magnitude options. |
| Mixture | |
| Available if you choose an External Conditions modeling object from the External Conditions list. | |
| Mixture | Specifies the mass fractions for the components of a mixture for the ambient fluid domain.NoneIndicates that there is no mixture entering the fluid domain.Homogeneous Gas MixtureSets the mass fractions for the homogenous mixture components.Immiscible Fluid MixtureSets the area fraction of the tracked fluid in the immiscible mixture entering the fluid enclosure. The area fraction value must be between 0 and 1, and it can vary with time in a transient analysis. If it is not defined, the flow solver assigns a value of 1. You define the value in the Tracked Fluid Area Fraction box. |
| Mixture Mass Fractions | Appears when Mixture is set to Homogeneous Gas MixtureSets the mass fractions for the homogenous mixture components.As a good practice, enter values from 0 to 1 for each mass fraction. If the sum of the mass fractions you enter is greater than 1, the values are normalized.You can use Cut , Copy , and Paste commands. |
How do I
Create a Flow Boundary Condition
Learn more
Flow Boundary Condition
Flow Boundary Condition types
Working with fan curves
Modeling heat loss or gain in a recirculation loop
Modeling fan swirl
Flow boundary condition modeling
External Conditions
Planar Head Loss
Look up more details
Flow Boundary Condition dialog box – Inlet Flow options
Flow Boundary Condition dialog box– Outlet Flow options
Flow Boundary Condition dialog box – Opening options
Flow Boundary Condition dialog box– Internal Fan options
Flow Boundary Condition dialog box – Recirculation Loop options
Flow Boundary Condition dialog box– Convective Outflow options
Flow Boundary Condition dialog box– Bursting Membrane options
Flow Boundary Condition dialog box– Flap options
Defining the mesh size for fluid modeling
Solution dialog box — Ambient Conditions
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal
Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions
Flow Boundary Condition dialog box – Static Pressure options, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid430202 · retrieved 2026-07-17