Transfer Admittance - Coefficients dialog box
| Modeling Object | |
|---|---|
| Name | Sets the name of the transfer admittance coefficients. |
| Label | Sets the label for the transfer admittance coefficients. |
| Properties | |
| Description | Sets a description for the transfer admittance coefficients. |
| The formulation matrix equation that links pressures with velocities is given by:where:P1 = Inlet pressureP2 = Outlet pressureVn1= Inlet velocityVn2 = Outlet velocityα1, α2, α4, α5 = Admittance coefficientsα3, α6 = Source coefficients | |
| Transfer Admittance Coefficients | |
| Alpha1/Alpha2/Alpha4/Alpha5 | Specifies how the transfer admittance coefficients are defined. |
| Real | Available when Alpha1/Alpha2/Alpha4/Alpha5 is set to Real/Imaginary.Sets the real component values of the transfer admittance coefficients. |
| Imaginary | Available when Alpha1/Alpha2/Alpha4/Alpha5 is set to Real/Imaginary.Sets the imaginary component values of the transfer admittance coefficients. |
| Magnitude | Available when Alpha1/Alpha2/Alpha4/Alpha5 is set to Magnitude/Phase.Sets the magnitude values of the transfer admittance coefficients. |
| Phase | Available when Alpha1/Alpha2/Alpha4/Alpha5 is set to Magnitude/Phase.Sets the phase angle values of the transfer admittance coefficients. |
| Specify Field | Available when Alpha1/Alpha2/Alpha4/Alpha5 is set to Field.Specifies the frequency dependent complex field values.Options include:Select Existing Field from List opens the Fields dialog box, where you can select a field.A field can define a magnitude that varies with independent variables such as frequency, temperature, or time. For more information about fields, see Fields.Formula Constructor opens the Formula Field dialog box, where you can define a formula to construct a field.For more information, see Define a boundary condition using a formula field.Table Constructor opens the Table Field dialog box, where you can define tabular data to construct a field.For more information, see Define a boundary condition using a table field and Define a material property using a table field.Plot (XY) plots the field as an XY graph.For more information, see Graph overview.Overlay (XY) overlays a plot on an existing plot. You can overlay up to 50 plots.For more information, see Overlay plots. |
| Internal Sources | |
| Alpha3/Alpha6 | Specifies how the internal sources coefficients are defined. |
| Real | Available when Alpha3/Alpha6 is set to Real/Imaginary.Sets the real component values of the internal sources coefficients. |
| Imaginary | Available when Alpha3/Alpha6 is set to Real/Imaginary.Sets the imaginary component values of the internal sources coefficients. |
| Magnitude | Available when Alpha3/Alpha6 is set to Magnitude/Phase.Sets the magnitude values of the internal sources coefficients. |
| Phase | Available when Alpha3/Alpha6 is set to Magnitude/Phase.Sets the phase angle values of the internal sources coefficients. |
| Specify Field | Available when Alpha3/Alpha6 is set to Field.Specifies the frequency dependent complex field values.Options include:Select Existing Field from List opens the Fields dialog box, where you can select a field.A field can define a magnitude that varies with independent variables such as frequency, temperature, or time. For more information about fields, see Fields.Formula Constructor opens the Formula Field dialog box, where you can define a formula to construct a field.For more information, see Define a boundary condition using a formula field.Table Constructor opens the Table Field dialog box, where you can define tabular data to construct a field.For more information, see Define a boundary condition using a table field and Define a material property using a table field.Plot (XY) plots the field as an XY graph.For more information, see Graph overview.Overlay (XY) overlays a plot on an existing plot. You can overlay up to 50 plots.For more information, see Overlay plots.Scale Factor — Sets the scaling of values present in the Field. |
Look up more details
Transfer Admittance dialog box (Acoustics BEM)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Transfer Admittance - Coefficients dialog box, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1380934 · retrieved 2026-07-17