Use the Test Analysis Reference Solution command to combine mode shapes from an existing normal modes solution with a wireframe, to visualize the shapes on the simplified version of the model.

Mode shapes from an existing normal modes solution that form a wireframe

Create a test analysis reference solution

You can create a test analysis reference solution from:

  • A pre-test solution process and sensor and exciter configurations.

  • A normal modes solution and a DOF set.

After it is created, you cannot update the solution even if the DOF sets or solver modes are out of date. You must create a new test analysis reference solution.

When you create a test analysis reference solution, the software automatically creates a node in the Simulation Navigator panel. The Test Analysis Reference Solution node contains the initial mode shape sensor set and mode shape results.

Test Analysis Reference Solution 1 Active
TAM for Test Analysis Reference Solution 1
Modes
Initial Mode Sensors[8] Active
Results
FRFs
Initial FRF Sensors[0] Active
No FRF Set Reference

Export a test analysis reference solution

You can export the Test Analysis Reference Solution to an UNV file for use in Simcenter Testlab or a third-party modal test software, or to a SC2TL file for use in Simcenter Testlab.

When exporting a Test Analysis Reference Solution, three types of nodes are written to the UNV or SC2TL files: sensor, exciter, and visualization nodes. Visualization nodes are referenced by wireframe elements or unattached nodes, which are not sensor or exciter nodes. In the SC2TL file, they are included in a component called VISU.

The solver identifies duplicate sensor and exciter nodes, and prevents potential conflicts due to different DOFs and displacement coordinate systems by creating new exciter nodes with different IDs and associated modes data. In the SC2TL file, the exporter creates a new component for each exciter, identifying the excitation DOFs. In the UNV file, the exporter creates a group for each duplicated exciter node, containing its ID and the ID of the sensor node.

Where do I find it?

Application Pre/Post
Prerequisite A pre-test solution process with one or more solved sensor and, optionally, exciter configurations, or a modal correlation solution process
Command Finder Test Analysis Reference Solution
Simulation Navigator Right-click the Pre-TestTest Analysis Reference Solution
How do I

Create a test analysis reference solution from a correlation solution process

Create a test analysis reference solution from a pre-test solution process

Look up more details

UNV datasets when exporting test analysis reference solution

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Test analysis reference solution, Simcenter 3D 2021.1 Series

© 2020 Siemens