Post-processing > Post processing with preconfigured views > Types of post-processing scenarios
Transfer Path Analysis (TPA) scenario (Simcenter Nastran FEM acoustics)
The Transfer Path Analysis post-processing scenario helps you to compute path contributions by visualizing loads, frequency response functions, and responses. It is available when the following data sources are available:
Loads from a load recipe or an external .op2 file of connection forces:Frequency-dependent forces on nodes (SORT2)Frequency-dependent vibrations on nodes (SORT2)
Frequency response functions (usually from a frequency response function (FRF) solution or an external file):Vibration or pressure over FRFsForce over vibration or pressure FRFsVibration over vibration FRFs
Responses (usually from SOL 108 or SOL 111 results or an external .op2 file):Frequency-dependent vibrations on nodes (SORT2)Frequency-dependent forces on nodes (SORT2)Frequency-dependent pressures on nodes
Use the Transfer Path Analysis scenario to visualize the following:
Total response
Projection of the selected node's contribution to the total response, to get only the in-phase part
The number of highest contributors within a frequency range and plotting them
Partial sum contributions for selected paths
Contributions as percentage of total response
A Transfer Path Analysis scenario that uses the:
Contributions - Stacked Plots definition consists of three XY graphs:Upper graph, which contains the loads.Middle graph, which contains the frequency response functions.Lower graph, which contains the response functions and the contributions.
Responses - Function Plots or Responses - Vector Plots definition consists of only one XY graph that shows contributions.
Parameters
The following table lists the parameters available for defining Transfer Path Analysis post-processing scenarios. They appear in the Parameters node of the Scenario Based Data-Visualization Navigator.
| Parameter | Definition |
|---|---|
| Show Total Response | Displays the total response, when all the modes or panels are considered. |
| Project Contributions on Total Response | Displays the projection of the selected mode or panel contribution functions on the total response. |
| Select Top Contributors | Lets you plot a selected number of highest contributors over the complete frequency range or over a defined frequency range from all the modes or panels available. You can use this to find the modes or panels which are the highest contributors in a given frequency range. |
| Number of Contributors | Available when the Select Top Contributors check box is selected.Sets the number of the highest contributors that you want to display. |
| Frequency Range | Displays the contributions in the specified range. |
| From / To | Available when the Frequency check box is selected.Sets the low and high range in the selected units. |
| Partial Sum Contribution | Displays a single plot that contains the partial sum from the selected modes or panels. |
| Include Individual Contributions | Available when the Partial Sum Contribution check box is selected.Displays the plots for the individual modes or panels along with the plot containing the partial sum from these selected modes or panels. |
| Show Contributions as % of Response | Displays the plots for the selected modes or panels as percentage of the total response. |
Learn more
Trim Analysis Results scenario (SOL 144)
Contour Plots scenario
Directivity Analysis scenario (Simcenter Nastran FEM acoustics and Acoustics BEM)
Duct Modes Transmission Coefficients scenario
Energy Contributions scenario (Simcenter Nastran FEM)
Equivalent Radiated Power scenario
Function Plots scenario
Grid Contribution scenario (Simcenter Nastran and MSC Nastran )
Inverse Numerical Acoustics (L-Curve) scenario
Matrix Comparison Plots scenario (Simcenter 3D NVH)
Maximum Analysis Frequency scenario (Acoustics BEM)
Motion Results scenario (Simcenter 3D Motion)
Waterfall to Order-Cut scenario (Simcenter Nastran FEM acoustics and Acoustics BEM)
Peakout Frequencies Plots scenario
Plotting contribution from panels, structural modes, fluid modes, and MATVs
Quality Metrics scenario
Random Results scenario (Simcenter Nastran FEM acoustics and Simcenter 3D Acoustics BEM)
Random VATV Forced Response Plots scenario
Ray Path Analysis scenario
Specialist Durability Function Definition scenario
Specialist Durability Plots scenario
Averaging scenario
Transmission Loss scenario (Simcenter Nastran FEM acoustics and Acoustics BEM)
Force Transmissibility scenario (Simcenter Nastran FEM acoustics)
Point Mobility scenario (Simcenter 3D NVH)
Load Identification scenario (Simcenter Nastran FEM)
Look up more details
BEM post-processing scenarios parameters
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Transfer Path Analysis (TPA) scenario (Simcenter Nastran FEM acoustics), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1396524 · retrieved 2026-07-17