Samcef environment > Samcef output requests
Time history graphs: superelement internal node results (Simcenter Samcef)
In a Simcenter Samcef nonlinear analysis, you can use Samcef Superelement Internal Node Output Request modeling objects to output the following time history result graphs on super elements:
Categories
Displacements-Rotations
| Sub Category | Simcenter Samcef codes |
|---|---|
| Displacement | 9163 |
Velocities
| Sub Category | Simcenter Samcef codes |
|---|---|
| Velocity | 9173 |
Accelerations
| Sub Category | Simcenter Samcef codes |
|---|---|
| Acceleration | 9183 |
Categories and sub-categories
You can use the Category list and the Sub Category list to select the result you want to define.
Degrees of freedom
In the DOFS group, select the degrees of freedom you want to enable for the result.
Nodes Selection
In the Select Nodes group, select the nodes to which you want to attach the result.
Where do I find it?
| Application | Pre/Post |
|---|---|
| Prerequisite | A Simulation file as the work part and displayed partSimcenter Samcef as the specified solverA nonlinear analysis as the active solution |
| Command Finder | Modeling Objects |
| Location in dialog box | Type list→ Samcef Superelement Internal Node Output Request |
Learn more
Default results (Simcenter Samcef)
Results codes in structural analyses (Simcenter Samcef Structure)
Families of results in structural and thermal output requests (Simcenter Samcef)
Results codes in thermal analysis (Simcenter Samcef Thermal)
User-defined output requests (Simcenter Samcef)
Time history graphs: nodal results (Simcenter Samcef structural nonlinear)
Time history graphs: element results (Simcenter Samcef structural nonlinear)
Time history graphs: nodal results (Simcenter Samcef linear transient)
Time history graphs: nodal results (Simcenter Samcef linear harmonic)
Time history graphs: element results (Simcenter Samcef linear transient or linear harmonic)
Time history graphs: nodal results (Simcenter Samcef thermal)
Time history graphs: element results (Simcenter Samcef thermal)
Time history graphs: superelement internal element results (Simcenter Samcef)
Code ID syntax for Simcenter Samcef solver results
Requesting additional results for analyses (Simcenter Samcef)
Modeling objects for specific results (Simcenter Samcef)
Result codes in superelement creation analysis (Simcenter Samcef)
Post-processing Macro (Simcenter Samcef Thermal)
Composite criteria results codes in structural analyses (Simcenter Samcef)
Damage tensor output requests (Simcenter Samcef)
Macro element (Simcenter Samcef)
Grid point force output requests (Simcenter Samcef)
Reaction in output requests (Simcenter Samcef Structure)
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Time history graphs: superelement internal node results (Simcenter Samcef), Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/xid1378634 · retrieved 2026-07-17