SimcenterKnowledge

Nastran environment > Nastran multi-step nonlinear analysis (SOLs 401 and 402)

Displaying graphs in the Solution Monitor using the Report simulation object

Depending on the solution type, you can use the Report simulation object to display graphs of displacements, velocity, or acceleration in the Solution Monitor during a solve. If you select multiple nodes to track, the graphs display the minimum, maximum, and average nodal values.

  • For SOL 401 Multi-Step Nonlinear, SOL 402 Multi-Step Nonlinear Kinematics, and Multi-Step Nonlinear, you can create Report simulation objects to display graphs of displacement.

  • For SOL 414,111 Harmonic Response Analysis and SOL 414,129 Transient Response Analysis, you can create Report simulation objects to display graphs of displacement, velocity, and acceleration.

You can access the graphs in the Solution Monitor from the Graphs list.

After the solve, the software saves a graph of displacements in the run directory in PNG format. You can save the values displayed in the graph to a CSV file by clicking Export in the graph window.

The Solution Monitor displays several other types of graphs that do not require a Report simulation object. For more information, see Simcenter Nastran graphs.

Corresponding Nastran Syntax

The Report simulation object corresponds to the Simcenter Nastran MONVAR case control command.

Where do I find it?

Creating the Report simulation object

Application Pre/Post
Prerequisite A Simulation file as the work part and displayed part Simcenter Nastran or Simcenter 3D Multiphysics as the specified solverStructural or Rotor Dynamics as the specified analysis typeFor Structural analyses, one of the following as the specified solution type:SOL 401 Multi-Step Nonlinear (Simcenter Nastran)SOL 402 Multi-Step Nonlinear Kinematics (Simcenter Nastran)Multi-Step Nonlinear (Multiphysics)For Rotor Dynamics analyses, one of the following as the specified solution type:SOL 414,111 Harmonic Response Analysis (Simcenter Nastran)SOL 414,129 Transient Response Analysis (Simcenter Nastran)
Command Finder Report

Displaying the Solution Monitor

Application Pre/Post
Prerequisites A Simulation file as the work part and displayed partSimcenter Nastran or Simcenter 3D Multiphysics as the specified solverStructural or Rotor Dynamics as the specified analysis typeFor Structural analyses, one of the following as the specified solution type:SOL 401 Multi-Step Nonlinear (Simcenter Nastran)SOL 402 Multi-Step Nonlinear Kinematics (Simcenter Nastran)Multi-Step Nonlinear (Multiphysics)For Rotor Dynamics analyses, one of the following as the specified solution type:SOL 414,111 Harmonic Response Analysis (Simcenter Nastran)SOL 414,129 Transient Response Analysis (Simcenter Nastran)Solution Monitor check box selected in the Solver Parameters dialog boxSolve in progress
Learn more

SOL 401 Multi-Step Nonlinear

SOL 401 Multi-Step Nonlinear workflow

SOL 402 Multi-Step Nonlinear Kinematics

SOL 402 Multi-Step Nonlinear Kinematics workflow

Modeling thermal strain

Controlling plasticity and creep effects

Controlling the sequence of bolt pre-loads (SOL 401)

Element Add/Remove (SOL 401)

Simcenter Nastran SOL 401 Co-simulation with Simcenter STAR-CCM+

Complex modes analysis (SOL 402)

Quick links

Command reference

Pre/Post video examples

Bulk Entry Descriptions

Simcenter 3D tutorials

Browse Simcenter 3D help by product area

Displaying graphs in the Solution Monitor using the Report simulation object, Simcenter 3D 2021.1 Series