Define Advanced Parameters
This example shows how to modify the temperature averaging algorithm for a solution using advanced parameters.
Choose Home tab→Loads and Conditions group→Advanced Controls .
In the Advanced Controls dialog box, select the Advanced Parameter from the Type list.
In the Parameter Definition group, click Catalog .
In the Catalog dialog box, in the Item list, click Thermal→Thermal Output→TEMPERATURE AVERAGING ALGORITHM and then click OK.
In the Advanced Controls dialog box, enter 2 in the Value box and click OK.The value, 2, specifies that the software must perform a weighted temperature averaging algorithm with respect to the element mass. For more information, see Thermal Solver TMG Reference Manual .
Click OK.
How do I
Define Generic Entities
Learn more
Inputs to expressions
Look up more details
Auto-generated expressions
Quick links
Simcenter 3D Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal boundary conditions
Thermal/Flow, Electronic Systems Cooling, and Space Systems Thermal
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
Define Advanced Parameters, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id628401 · retrieved 2026-07-17