The following table lists the datasets that are written to the UNV file when you right-click the Test Analysis Reference Solution node in the Simulation Navigator and select Export. This command exports the contents of Test Analysis Reference Solution to a UNV file that you can use with Simcenter Testlab or with a third-party software application.
| UNV dataset number | Selection | Comments |
|---|---|---|
| 82 | Tracelines | Tracelines are extracted from the selected groups containing 1D or 2D elements. Each exported traceline is named SC3DPreTest. When you import the UNV file in Simcenter Testlab, all the tracelines are part of a single component named SC3DPreTest. |
| 151 | Header | |
| 164 | Units | See Universal File Dataset Number 164. |
| 1802 | Coordinate Trace | A coordinate trace dataset is written for the selected sensor configuration or DOF set.A second coordinate trace dataset is written if an exciter configuration is selected. |
| 2400 | Model Header | |
| 2411 | Nodes | Active sensor, exciter and visualization nodes are written in the unit system that is defined by dataset 164. When exciters and sensors are on the same node, the solver creates new exciter nodes with different IDs. Node values are in double precision. See Universal File Dataset Number 2411. |
| 2414 | Mode Shapes | Active mode shapes are written for exciter, sensor and visualization nodes. The mode shapes are expressed in the local coordinate system of each node. Visualization node mode shape components are expressed in all 3 translational DOFs. Sensor and exciter node mode shape components are expressed in the coordinate trace DOFs. See Universal File Dataset Number 2414. |
| 2420 | Coordinate Systems | The origin is always written in SI units. Local coordinate systems are defined as follows: Visualization nodes: nodal displacement coordinate system in a Simulation file.Sensor and exciter nodes: nodal displacement coordinate system or virtual normal direction in a Simulation file. |
| 2477 | Groups | A group dataset is created for each new exciter node, indicating its ID and the ID of the sensor node. |
How do I
Create a test analysis reference solution from a correlation solution process
Create a test analysis reference solution from a pre-test solution process
Learn more
Test analysis reference solution
Quick links
Command reference
Pre/Post video examples
Bulk Entry Descriptions
Simcenter 3D tutorials
Browse Simcenter 3D help by product area
UNV datasets when exporting test analysis reference solution, Simcenter 3D 2021.1 Series
© 2020 Siemens
window.mainLanguage="en_US"
window.delivId=""
window.projectId=""
MathJax.Hub.Config({ TeX: { extensions: ["autoload-all.js"] }, tex2jax: { displayMath: [ ] }, "SVG": { scale: 125 } });
Source: https://docs.sw.siemens.com/en-US/doc/289054037/PL20200601120302950.advanced/id1221447 · retrieved 2026-07-17